Cdvsc7 series; cdv7 series direct vent gas fireplace
Table of Contents

Advertisement

CDVSC7 Series
CDV7 Series
Direct Vent Gas Fireplace
waRnInGS
IF The InFoRMaTIon In TheSe InSTRuCTIonS
aRe noT FolloweD exaCTly, a FIRe
oR exploSIon May ReSulT CauSInG
pRopeRTy DaMaGe, peRSonal InjuRy oR
loSS oF lIFe.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
whaT To Do IF you SMell GaS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
waRnInG: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSa
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases,
unless a certified kit is used.
* aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Models:
CDVR33n/pV7;n/pV117;n/pe7;n/pSC117,
CDVT33n/pV7;n/pe7;n/pSC7,
CDVR36n/pV7;n/pe7;n/pSC7,
CDVT36n/pV7;n/pe7;n/pSC7,
CDVR42npV7;npe7;n/pSC7,
CDVT42n/pV7;n/pe7;n/pSC7,
CDVR47n/pV7;n/pe7;n/pSC7,
CDVT47n/pV7;n/pe7;n/pSC7
Installation and Operating
Instructions
CDVT
WARNING
693011
CDVRT7 cover
AVERTISSEMENT
InSTalleR: leave this manual with the appliance.
ConSuMeR: Retain this manual for future refer-
ence.
CDVR
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Un panneau vitré chaud peut
causer des brûlures.
69D3011 11/13 Rev. 16
Laissez refroidir le panneau
vitré avant d'y toucher.
Ne laisser jamais les enfants
toucher le panneau vitré.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CDVR33n and is the answer not in the manual?

Questions and answers

jeremy
March 3, 2025

The pilot won't light

1 comments:
Mr. Anderson
March 3, 2025

The pilot on the Vermont Castings CDVR33n may not light due to the following reasons:
1. Gas Supply Issue – Check if the gas supply is turned on.
2. Gas Flow Path Obstruction – Inspect the gas flow path and ensure there are no blockages.
3. Sparker Position – Adjust the sparker position to ensure it is correctly aligned.
4. Faulty Pilot – If the pilot is still not lighting, it may need to be replaced.

This answer is automatically generated

Summary of Contents for Vermont Castings CDVR33n

  • Page 1 Models: CDVR33n/pV7;n/pV117;n/pe7;n/pSC117, CDVT33n/pV7;n/pe7;n/pSC7, CDVR36n/pV7;n/pe7;n/pSC7, CDVSC7 Series CDVT36n/pV7;n/pe7;n/pSC7, CDVR42npV7;npe7;n/pSC7, CDVT42n/pV7;n/pe7;n/pSC7, CDV7 Series CDVR47n/pV7;n/pe7;n/pSC7, CDVT47n/pV7;n/pe7;n/pSC7 Direct Vent Gas Fireplace Installation and Operating Instructions waRnInGS IF The InFoRMaTIon In TheSe InSTRuCTIonS CDVT aRe noT FolloweD exaCTly, a FIRe oR exploSIon May ReSulT CauSInG pRopeRTy DaMaGe, peRSonal InjuRy oR loSS oF lIFe.
  • Page 2: Table Of Contents

    CDVSC7 & CDV7 Series Gas Fireplace pleaSe ReaD The InSTallaTIon & opeRaTInG InSTRuCTIonS BeFoRe uSInG applIanCe. Thank you and congratulations on your purchase of a Vermont Castings Group fireplace. IMpoRTanT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    IMpoRTanT SaFeTy InFoRMaTIon CDVSC7 & CDV7 Series Gas Fireplace owneR InSTalleR Please retain these instructions for future reference. Please leave these instructions with the appliance. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    IMpoRTanT SaFeTy InFoRMaTIon CDVSC7 & CDV7 Series Gas Fireplace 1. Do not use this fireplace to cook food or burn paper or other objects. IMpoRTanT: pleaSe ReaD The FollowInG 13. Never place anything on top of fireplace. CaReFully 14. Do not use any solid fuels (wood, coal, paper, card- It is normal for fireplaces fabricated of steel board, etc.) in this fireplace.
  • Page 5: Product Specifications

    The appliance is not approved for closet installations. Ignitor • This appliance is approved to be vented with Duravent Blower FP84 Control and Vermont Castings Group Twist-Lock Direct Vent On/Off/RS Components. Figure 1 - Switch CDV7 Series Fireplace FP2284a The classification “noncombustible material” includes, but CDV7 controls is not limited to stone, brick and mortar.
  • Page 6: High Elevations

    pRoDuCT FeaTuReS & GaS SpeCIFICaTIonS CDVSC7 & CDV7 Series Gas Fireplace GaS pReSSuReS hIGh eleVaTIonS Input ratings are shown in BTU per hour and are certified Natural Propane (LP) without deration for elevations up to 4,500 feet (1,370 Inlet Minimum 5.5”...
  • Page 7: Fireplace & Framing Dimensions

    FIReplaCe DIMenSIonS & FRaMInG CDVSC7 & CDV7 Series Gas Fireplace Minimum Rough Opening Depth 5/8” 5/8” 1/2” 1/2” 1/2” or 5/8” P - Minimum Rough Opening Width Minimum Rough Opening Height 1 ” 5/8” 1/2” 1/2” 5/8” 15/16” Figure 2 - noTe: Models CDVR33SC7 &...
  • Page 8 FIReplaCe DIMenSIonS & FRaMInG CDVSC7 & CDV7 Series Gas Fireplace Minimum Rough Opening Depth 5/8” 5/8” 1/2” 1/2” 1/2” or 5/8” Q - Minimum Rough Opening Width Minimum Rough Opening Height 1 ” 5/8” 1/2” 1/2” 5/8” 15/16” Figure 3 - CDVT Series Fireplace Dimensions CDVT33(V,e,SC)7 CDVT36 (V,e,SC)7...
  • Page 9: Pre-Installation Information

    pRe-InSTallaTIon InFoRMaTIon CDVSC7 & CDV7 Series Gas Fireplace The firebox may be installed directly on a combustible floor BeFoRe you STaRT or raised on a platform of an appropriate height. When the Read this homeowner manual thoroughly and follow all firebox is installed directly on carpeting, tile, or other com- instructions carefully.
  • Page 10: Clearances

    3/4" from the facing. If it does, Mantel Clearances it is considered a mantel and must meet the mantel requirements listed in this manual. noTe: The Vermont Castings Group Barrington Cabinet FP2286 Mantel Model series BWC300, BWC400 and BWC500 are Mantel leg clear...
  • Page 11: Securing Fireplace To Floor Or Framing

    SeCuRe FIReplaCe To FlooR oR FRaMInG CDVSC7 & CDV7 Series Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown Drywall Support Tabs (Do in Figure 7. Use two () wood screws Not Use for Framing or Header) or masonry/ concrete screws to secure Framing...
  • Page 12: Venting Installation

    • Installation of any component part not manufactured the nearest vertical wall (1" required). a 1" or approved by Vermont Castings Group. minimum clearance all around the pipe must • Installation other than permitted by these instruc- be maintained at outside wall and on vertical tions.
  • Page 13: Termination Location

    3. Vermont Castings Group assumes no responsibility for  only permitted if veranda, porch, deck or balcony is fully open on a the improper performance of the appliance when the venting minimum  sides beneath the floor: system does not meet these requirements.
  • Page 14: Termination Clearances

    National Fuel Code ANSI Z3.1/NFPA 54. dure must be performed on the vent side. Only venting components manufactured or approved by Vermont Castings Group may be used in Direct Vent sys- tems. Canadian Installations The venting system must be installed in accordance with the current CSA-B149.1 installation code.
  • Page 15: Rear Vent Installation Only

    VenTInG InSTallaTIon InFoRMaTIon CDVSC7 & CDV7 Series Gas Fireplace TwIST loCk pIpeS ReaR VenT InSTallaTIon only: Install the 4” (10 mm) vent pipe to the appliance inner When using twist lock pipe it is not necessary to use seal- collar and secure with three (3) stainless steel sheet metal ant on the joints.
  • Page 16: How To Use The Vent Graph

    VenTInG InSTallaTIon InFoRMaTIon CDVSC7 & CDV7 Series Gas Fireplace how To uSe The VenT GRaph The Vent Graph should be read in conjunction with the following vent installation instructions to determine the re- lationship between the vertical and horizontal dimensions of the vent system.
  • Page 17: Vent Pipe Clearances

    VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace VenT pIpe CleaRanCeS A Minimum 1" C l e a r a n c e t o C o m b u s t i b l e s P e r m i t t e d A l l A Minimum 1"...
  • Page 18: Rear Wall Vent Application

    When installed as a rear vent unit this appliance may be (44 mm) Min. vented directly to a termination located on the rear wall behind the appliance. • Only Vermont Castings Group approved venting com- 9B\,” ponents are approved to be used in these applications (44 mm) Min.
  • Page 19 VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace Finish Wall Rise Vent Termination FP147 Figure 19 - There must be a 1/2" rise per foot length Top VenT SIDewall applICaTIon Figure 17 - noTe: For all top vent installations where a 90° elbow FP94 Side View of Final Unit Location is the first pipe piece towards a sidewall termination (up...
  • Page 20 VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace 3 x 90° 3 x 90° Elbows Elbows A + B = 17' (Max.) FP1176 (5.2m) Figure 21 - 7'6" Maximum three (3) 90° elbows per installation (2.3m) 36" (914mm) Figure 23 - FP1178 Max.
  • Page 21: Vertical Sidewall Installation

    VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace VeRTICal SIDewall InSTallaTIon - TwIST loCk pIpe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation. Depending on whether the wall is combustible or noncombustible, cut opening to size.
  • Page 22 VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace Step 6 Use appropriate length of pipe sections - telescopic or fixed - and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if 4”...
  • Page 23: Below Grade Installation

    VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace Below GRaDe InSTallaTIon Do not back fill around snorkel. When it is not possible to meet the required vent terminal a clearance of at least 4” must be maintained clearances of 1” (305 mm) above grade level, a snor- between the snorkel and the soil.
  • Page 24: Vertical Through-The-Roof

    VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace • For the minimum height of the vent above the highest VeRTICal ThRouGh-The-RooF point of penetration through the roof refer to Figure 38, InSTallaTIon Page 6. noTe: For all top vent vertical through-the-roof installa- tions, install the supplied cross-bar flue restrictor onto the top edge of the firebox flue adapter.
  • Page 25 VenTInG InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace 9. Install storm collar and seal around the pipe. Horizontal Overhang 10. Add additional vent lengths for proper height. Fig- ure 39 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install.
  • Page 26: Fireplace Installation

    FIReplaCe InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace CheCk GaS Type Use proper gas type for the fireplace you are installing. 100 lb. (min) If you have conflicting gas type, do not install fireplace. External Propane/LP See dealer where you purchased the fireplace for proper Regulator Supply Tank fireplace for your gas type or conversion kit.
  • Page 27 FIReplaCe InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace a manual shutoff valve must be installed only persons licensed to work with gas upstream of the appliance. union tee piping may make the necessary gas and plugged 1/8” npT pressure tapping connections to this appliance.
  • Page 28 CheCk GaS pReSSuRe & eleCTRICal InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STop! Do not install the appliance.
  • Page 29: Electrical Installation

    eleCTRICal InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace ReMoTe wall MounTeD SwITCh A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall Do not connect wall switch to (110 V) switch in a junction box at the desired location on the wall.
  • Page 30: Electronic Pilot Ignition Wiring

    eleCTRICal InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace eleCTRonIC pIloT IGnITIon wIRInG Do not connect 110-120 VaC to the Remote wall Switch. The appliance will malfunction. Pilot Assembly To Junction Box  Sense  Spark Ignition Module (Synetek)  GREEN WHITE  BLACK MAGENTA #5 BLACK WHITE  Primary - 120V Electronic Valve Transformer Secondary WHITE #3 GRAY #7...
  • Page 31: What To Do If You Smell Gas

    MIllIVolT opeRaTInG InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace FoR youR SaFeTy ReaD BeFoRe lIGhTInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 32: Lighting Pilot

    MIllIVolT opeRaTInG InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace lIGhTInG pIloT FoR The FIRST TIMe appRoVeD leak TeSTInG MeThoD You may check for gas leaks with the following methods only: If using a soap and water solution • to test for leaks, Do noT spray Soap and water solution solution onto control body.
  • Page 33: Lighting Burner

    MIllIVolT opeRaTInG InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace lIGhTInG BuRneR MaIn BuRneR SwITCh The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 34: What To Do If You Smell Gas

    eleCTRonIC IGnITIon opeRaTInG InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace FoR youR SaFeTy ReaD BeFoRe lIGhTInG a. This appliance is equipped with an ignition device (Piezo) which automatically lights the pilot. Do NOT If you do not follow these instruction try to light the burner by hand.
  • Page 35: Electrical Wiring

    SIGnaTuRe CoMManD - CheCk GaS pReSSuRe and eleCTRICal InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace 1. Check gas type. The gas supply must be the same as Pressure Inlet stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STop! Do not install the appliance.
  • Page 36: Junction Box Wiring

    eleCTRICal InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace junCTIon Box wIRInG 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with mini- mum 60° C wire in accordance with prevailing codes. . Remove the external junction box cover by removing the screw from the side of the outside firebox wall.
  • Page 37: Signature Command System Wiring Diagram

    eleCTRICal InSTallaTIon CDVSC7 & CDV7 Series Gas Fireplace Optional To Junction Box AC Module in Fireplace Pilot Optional White Light Black Optional White Blower Black White Optional Black Aux. Green Connector Pin To Control Board Input 300 Watt Max. Each Optional A/C Module Replaces 6V Adapter When Used RF Receiver ON/OFF Button Control Board 6V AC Black / Thermopile Adapter Red / Thermopile Sensor Conversion NG/LP Ignitor / Sparker Plug-in Connector...
  • Page 38: Optional Fan/Blower System - Scs

    opTIonal Fan BloweR SySTeMS CDVSC7 & CDV7 Series Gas Fireplace electrical Grounding Instructions: This electrical connections should only be appliance is equipped with a three-prong performed by a qualified licensed electrician. (grounding) plug for your protection against Main power supply must be turned off before shock hazard and should be plugged directly connecting the fan to the main electrical into a properly grounded three-prong...
  • Page 39: Blot Automatic Thermostat Blower

    opTIonal Fan BloweR SySTeMS CDVSC7 & CDV7 Series Gas Fireplace BloT auToMaTIC TheRMoSTaT BloweR 120VAC Receptacle  Junction  BLACK GREEN FP675 WHITE BLACK WHITE BLACK BLACK Speed Control  Before installing the blower, wire the receptacle into an Figure 51 - electrical circuit. This should be done before framing the BLOT Blower Wiring Diagram fireplace.
  • Page 40: What To Do If You Smell Gas

    opeRaTInG InSTRuCTIonS - SIGnaTuRe CoMManD CDVSC7 & CDV7 Series Gas Fireplace FoR youR SaFeTy ReaD BeFoRe lIGhTInG If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. a.
  • Page 41: Operating Instructions

    opeRaTInG InSTRuCTIonS - SIGnaTuRe CoMManD CDVSC7 & CDV7 Series Gas Fireplace opeRaTInG InSTRuCTIonS 1. STop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 42: Signature Command System

    SIGnaTuRe CoMManD SySTeM opeRaTIon InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace FeaTuReS To Thermopile RF Receiver ON/OFF To Sensor Command Center To Sparker • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ NG/LP Buzzer) Conversion •...
  • Page 43: Operation Instructions

    SIGnaTuRe CoMManD SySTeM opeRaTIon InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace SySTeM ConFIGuRaTIon/SeTup noTe: By disabling this feature, your fireplace may con- tinue to operate unattended. All System configuration/setup is done on the Command . When the master switch is in the ON position (“-”), press- Center.
  • Page 44 SIGnaTuRe CoMManD SySTeM opeRaTIon InSTRuCTIonS CDVSC7 & CDV7 Series Gas Fireplace FunCTIonS/opeRaTIon 3. The third press on OFF will turn off the main burner. In Turning on the fireplace standing pilot configuration, the pilot will stay; in inter- mittent pilot configuration, the pilot will be shut off. 1.
  • Page 45: Glass Removal

    GlaSS ReMoVal & RoCk wool plaCeMenT CDVSC7 & CDV7 Series Gas Fireplace GlaSS FRaMe ReMoVal 1. Remove upper and lower louvers. . Release the clamps on the bottom of the fireplace. Figure 54 3. Tilt glass frame out and lift glass frame up until it clears the hook on top of the frame.
  • Page 46: Log Placement

    loG plaCeMenT CDVSC7 & CDV7 Series Gas Fireplace loG plaCeMenT laVa RoCk anD eMBeR plaCeMenT Figure 56 Sprinkle lava rock on the floor of the inner combustion 1. Place rear log (#1) on grate assembly. Log should rest chamber. Evenly distribute the rock. Do not pile the lava firmly on the two log mounting pins shown.
  • Page 47: Cleaning And Maintenance

    CleanInG anD MaInTenanCe CDVSC7 & CDV7 Series Gas Fireplace Thermocouple Turn off gas before servicing fireplace. It Thermopile is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BuRneR, pIloT anD ConTRol CoMpaRT- MenT Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at...
  • Page 48: Vent System

    CleanInG anD MaInTenanCe CDVSC7 & CDV7 Series Gas Fireplace loGS VenT SySTeM Leave logs installed in the fireplace for cleaning. Vacuum The fireplace and venting system should be inspected surface of the logs with a brush attachment. If logs must be before initial use and at least annually by a qualified field removed for cleaning, handle carefully by holding gently at service person.
  • Page 49: Troubleshooting

    TRouBleShooTInG CDVSC7 & CDV7 Series Gas Fireplace STanDInG pIloT IGnITIon SyMpToM poSSIBle CauSe aCTIon 1. Spark ignitor will A. Wire disconnected. A. Open door and check to make sure wire is connected to not light pilot after ignitor. repeated triggering of B.
  • Page 50: Standing Pilot Ignition

    TRouBleShooTInG CDVSC7 & CDV7 Series Gas Fireplace STanDInG pIloT IGnITIon SyMpToM poSSIBle CauSe aCTIon 4. Frequent pilot A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame outage problem. or too low, causing pilot impingement on thermocouple.
  • Page 51 TRouBleShooTInG CDVSC7 & CDV7 Series Gas Fireplace eleCTRonIC IGnITIon STaRT Check: Line voltage (10VAC) Low voltage transformer (19.5 minimum VAC) 1. Turn gas supply off. ON/OFF switch . Turn ON/OFF switch to “ON” Wiring connections Power to module (4V Normal) Unplug ignition lead and check spark at module Is there a spark across...
  • Page 52: Signature Command System

    TRouBleShooTInG CDVSC7 & CDV7 Series Gas Fireplace SIGnaTuRe CoMManD SySTeM ACTION  OPERATION  FAULT  DIAGNOSIS  Using  Battery polarity wrong?  Re-install batteries  battery?  Make sure  Command  Install batteries and/or  Battery voltage low?  Change batteries  Center and  plug in the AC board  A  No beep in about  the control  8 seconds  board are  connected by  a 2 feet or 15  AC plug is plugged to  Plug the AC plug to   feet cable  AC mains?  AC mains  Flip the master switch  The 5-pin connector on  Repair or replace the   (rocker switch) to the  ...
  • Page 53: Replacement Parts

    ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace FIReBox CoMponenTS (CDVT Series) (CDVR Series) 7,10,11,13 69D3011...
  • Page 54 ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace FIReBox CoMponenTS Item Description qty. CDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standard Features Junction Box Assy 6D18K 6D18K 6D18K 6D18K 6D18K 6D18K 6D18K 6D18K Black Louver 54D046 54D046 6D0695 6D0695 6D0697 6D0697 6D0699...
  • Page 55: Standing Pilot - Millivolt Control

    ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace STanDInG pIloT — MIllIVolT ConTRol 11,12,13,14 693011 CDV millivolt parts 69D3011...
  • Page 56 ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace STanDInG pIloT – MIllIVolT ConTRol Item Description qty. CDV33nV7(117) CDV33pV7(117) CDV36nV7 CDV36pV7 CDV42nV7 CDV42pV7 CDV47nV7 CDV47pV7 Gas Valve Assy. 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 Pilot Assembly 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019 37D0018...
  • Page 57: Electronic Ignition

    ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace eleCTRonIC IGnITIon Item Description qty. CDV33ne7 CDV33pe7 CDV36ne7 CDV36pe7 CDV42ne7 CDV42pe7 CDV47ne1 CDV47pe7 Gas Valve Assy. 37D0016 37D0017 37D0016 37D0017 37D0016 37D0017 37D0016 37D0017 Pilot Assembly 37D000 37D001 37D000 37D001 37D000 37D001 37D000 37D001 Burner Tube...
  • Page 58: Signature Command System

    ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace SIGnaTuRe CoMManD SySTeM 13,14,15,16,17 693011 cdvrt7 SC parts 69D3011...
  • Page 59 ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace SIGnaTuRe CoMManD SySTeM Item Description qty. CDVR33 CDVR33 CDVT33 CDVT33 CDV(R,T)36 CDV(R,T)36 CDV(R,T)42/47 CDV(R,T)42/47 nSC117 pSC117 nSC7 pSC7 nSC7 pSC7 nSC7 pSC7 1. Gas Valve Assy. 80D0001 80D000 80D0001 80D000 80D0001 80D000 80D0001 80D000 .
  • Page 60: Logs

    ReplaCeMenT paRTS CDVSC7 & CDV7 Series Gas Fireplace loGS Item Description CDVR33SC117 CDVR33(V,e)7 CDV(R,T)36(V,e,SC)7 CDV(R,T)42(V,e,SC)7 CDV(R,T)47(V,e,SC)7 693011 Rear Log 03010 54D011 54D0181 54D0339 54D0339 Right Log 54D0147 54D0147 54D0116 54D0361 54D0361 cdv log parts Left Log 54D0146 54D0146 54D0115 54D0360 54D0360 69D3011...
  • Page 61: Venting Components

    VenTInG CoMponenTS CDVSC7 & CDV7 Series Gas Fireplace VeRTICal VenTInG Description Model number Vertical Vent Termination Kits Vertical Vent Termination w/ Storm Collar 7TDVSKV (flashing NOT included) Vertical Vent Termination w/ Storm Collar - 8 pack 7TDVSKV/8 (flashing NOT included) Vertical Vent Termination w/ 1/1 - 6/1 Flashing, Storm 7TDVSKVA* Collar and Ceiling Support Kit...
  • Page 62: Horizontal Venting

    VenTInG CoMponenTS CDVSC7 & CDV7 Series Gas Fireplace hoRIZonTal VenTInG Description Model number Horizontal Vent Termination Kits Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10" to 16" 7TDVSCTK Adjustable Termination Pipe, 90°...
  • Page 63 VenTInG CoMponenTS CDVSC7 & CDV7 Series Gas Fireplace VenT CoMponenTS FoR 4" x 6B\," (Duravent, Selkirk) Current 4" x 6Z\x" (Metal-Fab) Duravent Duravent or Vermont or Vermont qty./ Castings Group Castings Group Selkirk Metal-Fab Item Box Description part no. part no. part no.
  • Page 64 CDVSC7 & CDV7 Series Gas Fireplace 69D3011...
  • Page 65 CDVSC7 & CDV7 Series Gas Fireplace 69D3011...
  • Page 66 CDVSC7 & CDV7 Series Gas Fireplace Massachusetts Residents only — please read and follow these special requirements noTe ReGaRDInG VenTeD pRoDuCTS . approved Carbon Monoxide Detectors. Each carbon This product must be installed by a licensed plumber or gas fitter monoxide detector as required in accordance with the above when installed within the Commonwealth of Massachusetts.
  • Page 67: Warranty

    Vermont Castings Group in the appliance are found to be defective in materials or workmanship, Vermont Castings Group will, at its option, replace or repair the defective components at no charge to the original owner. Vermont Castings Group will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation.
  • Page 68 55.4 CDVR36PE7 56.1 CDVT4PV7 64.3 CDVR36PSC7 56.1 CDVT4PE7 67.6 CDVR4PV7 68.7 CDVT4PSC7 67.6 CDVR4PE7 7.3 CDVT47PV7 6.4 CDVR4PSC7 7.3 CDVT47PE7 65.7 CDVR47PV7 67.1 CDVT47PSC7 65.7 CDVR47PE7 70.6 CDVR47PSC7 70.6 Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...