PRODUCT FEATURES
PRODUCT SPECIFICATIONS
• This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
• This appliance is not for use with solid fuels.
• The appliance is approved for bedroom or bedsitting
room installations.
• The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
• This appliance is mobile home approved.
• The appliance must be properly connected to a venting
system.
• The appliance is not approved for closet or recessed
installations.
WARNING
Do not remove insulation board.
GAS PRESSURES
Inlet Minimum
Inlet Maximum
Manifold Pressure
Figure 1 -
500DVM and 600DVM Fireplace
(Millivolt Unit Shown —
Also Available with
Signature Command System)
20306747
Natural
Propane (LP)
4.0" w.c.
11.0" w.c.
14.0" w.c.
13.0" w.c.
3.5" w.c.
10.0" w.c.
Standoff
Insulation
Board
Eyebrow
Hi/Lo Knob
Off/Pilot/On Knob
On/Off/RS Switch
FP2407
DVM Series Direct Vent Gas Fireplace
GAS SPECIFICATIONS & ORIFICE SIZE
Model
500DVMNSC
600DVMNSC
500DVMPSC
600DVMPSC
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installa-
tions must be in accordance with the current ANSI Z223.1/
NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations above
4,500 feet (1,370 m).
Ignitor
Blower Control
Optional Remote Receiver
Max.
Min.
Input
Input
Fuel
BTU/h
BTU/h
Nat.
30,000
21,500
Nat.
32,000
22,000
LP
30,000
23.500
LP
32,000
26,000
1/2"
Nailing
Flange
5/8" Nailing
Flange
1/2"
Nailing
Flange
FP2407
Orifice
Size
7/64"
#34
#51
#50
5