Electrical wiring must conform with National Electrical
Code ANSI/NFPA No. 70 in United States and CSA C22.1
Canadian Electrical Code in Canada and/or the local
authority having jurisdiction.
•
Separate electrical circuit should be run from entry
box with fused disconnect switch in this circuit.
•
See wiring diagrams in
suggested circuitry and field wiring see Normal
Sequence of Operation in this manual.
•
Wiring for zone valve installations are furnished with
zone valve packages.
Wiring Code
LINE VOLTAGE BY FACTORY
LOW VOLTAGE BY FACTORY
LINE VOLTAGE BY INSTALLER
LOW VOLTAGE BY INSTALLER
* Not all components listed are used in all control
systems.
Figure 12 - Wiring Diagram For Oil Fired Boilers Less Tankless Heater
ELECtRICAL WIRINg
Figures 12 & 13, for
Component Coding
TH-1
Thermostat (millivolt)
TH-2
Thermostat (24 Volt)
TH-3
Thermostat (Line Voltage)
TR-1
Transformer (120V/24V 40VA)
TR-2
Transformer (120V/24V 50VA)
LGV
24 Volt Gas Valve
PS
Pressure Switch
MR-PS
Manual Reset Pressure Sw.
Control Terminal
1K
Relay Coil
1K1
Relay Contacts
1K2
Relay Contacts
LS
Limit Switch
MS
Manual Switch
CIR
Circulator
ECO
Energy Cut-Off
PSC
Pilot Safety Coil
Wire Connection
LWCO
Low Water Cut Off
EWF
Electric Water Feeder
PG
Power Generator