• Circuit Breaker. The circuit breaker may trip when
the scooter is under excessive loads or when
travelling on steep inclines. It will be more prone to
tripping when the scooter is low on battery charge.
Under normal conditions the circuit breaker button
will protrude by 2mm – 3mm. If the circuit breaker
has tripped the button will protrude by 7mm. to rest
the circuit breaker, push the button in and the
scooter should operate as normal.
• Freewheel Lever
Warning
The lever should only be set to
FREEWHEEL when on flat ground and
unoccupied by the user. Otherwise, there
is a risk of damage or injury.
Prism Electric Scooter
Engaged (Drive)
Mode:
Push the lever down
completely and the
scooter can be driven
by the motor.
Freewheel Mode:
Pull the lever up and
switch the scooter off.
The scooter can now
be pushed / moved
manually.
• Tiller Adjustment
The tiller can be adjusted in to many different positions
to suit each user. To adjust follow the steps below:
1.
Loosen the knob (as shown by the lower hand
in the photo) so the tiller can move.
2. Using the other, reposition the tiller as required
then retightened the knob to secure.