Summary of Contents for Thomas & Betts Sta-Kon PAIR22-6
Page 1
Operating Instructions for PAIR22-6 AIR-POWERED CRIMPING TOOL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents Page Page ..................1.0 GENERAL INFORMATION 4.0 MAINTENANCE 5 & 6 1.1 Description 4.1 Each Operating Day 1.2 Safety...
GENERAL INFORMATION IDENTIFICATION DESCRIPTION All speci cations are nominal and may change as The PAIR22-6 Air-powered Hydraulic Crimping Tool is a portable, Sta-Kon crimping tool intended to ® design improvements occur. Thomas & Betts shall crimp terminals on 22 AWG thru 6 AWG wire using not be liable for damages resulting from appropriate dies.
IMPORTANT SAFETY INFORMATION SAFETY ALERT SYMBOL This symbol is used to call your attention to hazards or unsafe WARNING practices which could result in an injury or property damage. The Hazards which, if not avoided, COULD result in severe signal word, de ned below, injury or death.
OPERATION SET UP TOOL TOOL OPERATION The tool is shipped fully assembled (less dies). 1. To operate the tool properly, it is essential to hold the actuating handle (see Figure 1) down 1. Remove tool assembly from shipping container. until the tool cycles completely. This assures a 2.
OPERATION..Continued CRIMPING CABLE Sta-Kon Terminals 1. Using release knob (see Figure 1), open spring ® loaded lower die. One crimp required. 2. Insert the terminal into the proper crimping head die nest, and allow lower die to close. Non Insulated Insulated 3.
MAINTENANCE..Continued FILL TOOL WITH HYDRAULIC OIL 1. Unscrew hydraulic cylinder from air cylinder Low Oil (see Figure 4). Warning Cylinder 2. Hold tool upright with air cylinder ar top; pull the Device two cylinders completely apart. 3. Pour hydraulic oil (T&B Cat. No. 21061) through opening in packing gland until oil level reaches top of gland.
CALIBRATION VERIFICATION..Continued GAGING PROCEDURE GAGING TABLES NOTE: Wipe die nest before gaging. TABLE 2 1. Cycle tool until dies bottom. DIE2001 GAGING REQUIREMENTS 2. Using gage pins, insure that each nest meets the GAGING gaging requirements as speci ed in TABLE 2, 3, NEST WIRE SIZE 4, 5, or 6 per the corresponding die.