Microwave/Convection Oven; Power Ventilation System; Central Vacuum System (Optional); Horn - Sea Ray 44 Sedan Bridge Owner's Manual

Table of Contents

Advertisement

S
ECTION
supplies power to the stove and must be ON to
operate the stove.
The stove has two (2) burners with control knobs
to provide a variation of heat.
A stove cover is provided to cover the burners when
not in use. A power safety switch is installed on the
cover recess. When the stove cover is installed it
depresses the switch turning power OFF to the
stove control knobs. When using the stove, the
stove cover can be stored in the rack on the forward
wall of the cabinet directly below the stove.
REFER TO OWNER'S MANUAL PACKET FOR
INSTRUCTIONS AND WARRANTY INFORMATION.
B. M
/C
ICROWAVE
ONVECTION
The microwave/convection oven is located above
the refrigerator/freezer in the galley. The 120VAC
MICROWAVE breaker on the AC Main Distribution
panel supplies power to the microwave and must
be ON to operate the unit.
NOTE: Turn on the galley power ventilation system
when operating the convection oven.
REFER TO OWNER'S MANUAL PACKET FOR
INSTRUCTIONS AND WARRANTY INFORMATION.
15. P
V
OWER
ENTILATION
The power ventilation system removes stagnant &
foul air from the master stateroom head, galley and
guest head by means of exhaust fans. They are
powered by the POWER VENTS breaker on the
DC main distribution panel in the salon and
individually turned on and off by the power vent
switch in the heads and the galley.
16. C
V
ENTRAL
ACUUM
The central vacuum unit is located under the port
bunk in the guest stateroom. The CABIN MAIN
breaker must be ON to operate the system.
7.16
7 • A
CCESSORIES AND
O
VEN
S
YSTEM
(O
)
PTIONAL
O
PTIONS
The supplied 24 foot hose connects to the central
vacuum through the hose inlet which is located
under the guest stateroom hanging closet.
The built in switch on the hose inlet fittings activate
the vacuum when the hose is inserted. The
disposable bag is located under the removable
panel on the top of the vacuum unit.
C
V
S
ENTRAL
ACUUM
YSTEM
(F
. 7.16.1)
IG
A
CENTRAL VACUUM CLEANER
B
VACUUM HOSE INLET
17. H
ORN
The horn, located in the
starboard bow chain locker is
protected by a breaker on the
control station breaker panel
which can be accessed
through the door underneath
the helm. The compressor for
the horn can be accessed
through the hatch located under the master
stateroom bunk.
To activate the horn, depress the HORN switch on
the control station switch panel.
44 Sedan Bridge (455 Sedan Bridge)
(O
)
PTIONAL
A
B

Advertisement

Table of Contents
loading

Table of Contents