3. Be sure the torch and work cable rubber cover-
ings are free of cuts and cracks that allow high
frequency leakage. Cables with high natural rub-
ber content, such as Lincoln Stable-Arc
resist high frequency leakage than neoprene and
other synthetic rubber insulated cables.
4. Keep the torch in good repair and all connections
tight to reduce high frequency leakage.
5. The work terminal must be connected to a ground
within ten feet of the welder, using one of the fol-
lowing methods.
a) A metal underground water pipe in direct con-
tact with the earth for ten feet or more.
b) A 3/4" (19mm) galvanized pipe or a 5/8"
(16mm) solid galvanized iron, steel or copper
rod driven at least eight feet into the ground.
The ground should be securely made and the
grounding cable should be as short as possible
using cable of the same size as the work cable, or
larger. Grounding to the building frame electrical
conduit or a long pipe system can result in re-radi-
ation, effectively making these members radiating
antennas.
6. Keep all panels securely in place.
7. All electrical conductors within 50 ft (15.2m) of the
welder should be enclosed in grounded, rigid
metallic conduit or equivalent shielding. Flexible
metallic conduit is generally not suitable.
8. When the welder is enclosed in a metal building,
several earth driven electrical grounds connected
(as in 5b above) around the periphery of the build-
ing are recommended.
Failure to observe these recommended installation
procedures can cause radio or TV interference prob-
lems.
INSTALLATION

INPUT CONNECTIONS

Be sure the voltage, phase, and frequency of the input
®
better
power is as specified on the rating plate, located on
the bottom of the machine.
ELECTRIC SHOCK can kill.
Allow machine to sit for 5 minutes minimum to
allow the power capacitors to discharge before
working inside this equipment.
• Do not touch electrically hot parts.
• Machine must be plugged into a receptacle that
is grounded according to the National Electrical
Code and local codes.
• Do not remove or defeat the purpose of the
power cord ground pin.
-----------------------------------------------------------------------

RECONNECT PROCEDURE

The Invertec V205-T AC/DC auto reconnects to either
115V or 230V supply.
Fuse the input circuit with the time delay fuses or
delay type
breakers smaller than recommended may result in
"nuisance" shut-offs from welder inrush currents even
if not welding at high currents.
The Invertec V205-T AC/DC is recommended for use
on an individual branch circuit.
1
Also called "inverse time" or "thermal/magnetic" circuit breakers.
These circuit breakers have a delay in tripping action that
decreases as the magnitude of the current increases.
V205-T AC/DC TIG
WARNING
• Have a qualified electrician install
and service this equipment.
• Turn the input power OFF and unplug
the machine from the receptacle
before working on this equipment.
1
circuit breakers. Using fuses or circuit
A-3