Select Suitable Location; Stacking; Tilting; Environmental Area - Lincoln Electric invertec v205-t Operator's Manual

Ac/dc tig
Hide thumbs Also See for invertec v205-t:
Table of Contents

Advertisement

A-2
Read entire installation section before starting
installation.
Safety Precautions
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
•Turn the input power OFF and unplug
the machine from the receptacle
before working on this equipment. Allow machine to
sit for 5 minutes minimum to allow the power
capacitors to discharge before working inside
this equipment.
• Insulate yourself from the work and ground.
• Always wear dry insulating gloves.
• Always connect the V205-T to a power supply
grounded according to the National Electrical
Code and local codes.
------------------------------------------------------------

SELECT SUITABLE LOCATION

The Invertec will operate in harsh environments. Even
so, it is important that simple preventative measures
are followed in order to assure long life and reliable
operation.
• The machine must be located where there is free cir-
culation of clean air such that air movement in the
back and out the front will not be restricted.
• Dirt and dust that can be drawn into the machine
should be kept to a minimum. Failure to observe
these precautions can result in excessive operating
temperatures and nuisance shutdown.

STACKING

The Invertec V205-T AC/DC can not be stacked.

TILTING

Place the machine directly on a secure, level surface.
The machine may topple over if this procedure is not
followed.

ENVIRONMENTAL AREA

Keep the machine dry. Do not place it on wet ground
or in puddles.
INSTALLATION
MACHINE GROUNDING AND HIGH FRE-
QUENCY INTERFERENCE PROTECTION
The Capacitor Discharge Circuit used in the high fre-
quency generator, can be blamed for many radio, TV
and electronic equipment interference problems.
These problems may be the result of radiated interfer-
ence. Proper grounding methods can reduce or elimi-
nate radiated interference.
The Invertec V205-T AC/DC has been field tested
under recommended installation conditions. It com-
plies with FCC allowable limits for radiation.
Radiated interference can develop in the following
four ways:
1. Direct interference radiated from the welder.
2. Direct interference radiated from the welding leads.
3. Direct interference radiated from feedback into the
power lines.
4. Interference from re-radiation of "pickup" by
ungrounded metallic objects.
Keeping these contributing factors in mind, installing
equipment per the following instructions should mini-
mize problems.
1. Keep the welder power supply lines as short as
possible and enclose as much of them as possible
in rigid metallic conduit or equivalent shielding for a
distance of 50 feet (15.2m). There should be good
electrical contact between this conduit and the
welder case ground. Both ends of the conduit
should be connected to a driven ground and the
entire length should be continuous.
2. Keep the work and electrode leads as short as
possible and as close together as possible.
Lengths should not exceed 25 ft (7.6m). Tape the
leads together when practical.
V205-T AC/DC TIG
A-2