6-1. IC PIN FUNCTION DESCRIPTION

• MAIN BOARD IC301 µPD780016YGF-015-3BA (MASTER CONTROLLER)
Pin No.
Pin Name
1
TA-MUTE
2
DBFB-H/L
3
427-LAT
4
K-CON-LAT
5
K-CON-ON
6
F-RELAY
7
R-RELAY
8
PL-RELAY
9
TEST
10
X2
11
X1
12
VDD
13
XT2
14
XT1
15
RESET
16
(INT/IN)
17
(INT/IN/OUT)
18
SCOR
19
SOFT-TEST
TE
L 13942296513
20
AC-CUT
21
RDS-INT
22
RDS-DATA
23
VDD
24
AVDD
25
ADJ
26
A-SHUT
27
B-SHUT
28
B-HALF
29
CLK-CHECK
30
SPEC-IN
31
ADJ2
32
DEMO-MODE
33
AVSS
34
SQ-DATA-IN
35
36
D.OUT ON/OFF
37
SW-ON/OFF
38
FUNC1
39
FUNC2
www
40
VSS
41
VOL-LAT
42
PL-LAT
.
43
COM-DIN
44
COM-DOUT
http://www.xiaoyu163.com
SECTION 6

DIAGRAMS

I/O
O
Line mute control signal output terminal "L": mute on
O
DBFB normal/high selection signal output terminal "L": DBFB high, "H": DBFB low
O
Serial data latch pulse output to the electrical volume (IC201)
O
Serial data latch pulse output to the key control (IC1401)
O
On/off selection signal output of the key control circuit "L": on
O
Relay drive signal output for the main speaker (front speaker) "H": on
O
Relay drive signal output for the surround speaker "H": on
O
Relay drive signal output for the surround speaker "H": on
I
Connected to ground
O
Main system clock output terminal (5 MHz)
I
Main system clock input terminal (5 MHz)
Power supply terminal (+5V)
O
Sub system clock output terminal (32.768 kHz)
I
Sub system clock input terminal (32.768 kHz)
System reset signal input from the reset signal generator (IC302)
I
hundreds msec. after the power supply rises, "L" is input, then it changes to "H"
I
Connected to ground
I
Connected to ground
O
Subcode sync (S0+S1) detection signal input terminal Not used (fixed at "L")
O
Output terminal for the software test (open)
I
AC off detection signal input from the reset signal generator (IC302)
I
Serial data reading clock signal input for the radio data system Not used (fixed at "L")
I
Serial data input for the radio data system Not used (open)
Power supply terminal (+5V)
Power supply terminal (+5V) (for A/D conversion)
I
Setting terminal for the test Normally: "H"
I
Shut off detection signal input from the deck-A reel pulse detector (Q1001)
I
Shut off detection signal input from the deck-B reel pulse detector (Q1002)
I
Detection input from the deck-B half detect switch (S1007)
I
Not used (fixed at "L")
I
Setting terminal for the version Fixed at "L"
I
Setting terminal for the test Normally: "L"
I
Setting terminal for the demonstration H/L Fixed at "L"
Ground terminal (for A/D conversion)
I
Sub-code Q data input terminal Not used (fixed at "L")
Not used (open)
O
Power on/off selection signal output for the CD digital out optical "H": power on
O
Not used (open)
I
Setting terminal for the function 1 Fixed at "L"
I
Setting terminal for the function 2 Fixed at "L"
Ground terminal
O
Serial data latch pulse output terminal Not used (open)
x
ao
u163
y
O
Serial data latch pulse output terminal Not used (open)
i
I
Serial data input terminal Not used (fixed at "L")
Serial data output to the electrical volume (IC201), DJ effect controller (IC401), and key
O
control (IC1401)