■ CONFIRMATION OF IDLING CURRENT OF AMP UNIT

● Right after power is turned on, confirm that the voltage across the terminals of R1152 (SURROUND BACK Rch), R1154
(SURROUND Rch), R1150 (FRONT Rch), R1148 (CENTER), R1149 (FRONT Lch), R1153 (SURROUND Lch), R1151
(SURROUND BACK Lch) are between 0.1mV and 10.0mV.
● If it exceeds 10.0 mV, open (cut off) R1104 (SURROUND BACK Rch), R1106 (SURROUND Rch), R1102 (FRONT Rch),
R1100 (CENTER), R1101 (FRONT Lch), R1105 (SURROUND Lch), R1103 (SURROUND BACK Lch) and reconfirm the
voltage.
Attention
If the measured voltage exceeds 10.0mV after an amplifier repair, first check for a defective component before cutting
the bias resistor.
● Confirm that the voltage is 0.2 mV to 15.0 mV after 60 minutes.
0.1 mV – 10.0 mV
(DC)
R1154
R1106
MAIN (1) P.C.B.
R1152 (SURROUND BACK Rch)
R1154 (SURROUND Rch)
R1150 (FRONT Rch)
R1148 (CENTER)
R1149 (FRONT Lch)
R1153 (SURROUND Lch)
R1151 (SURROUND BACK Lch)
Front side
R1153
R1152
R1151
R1104
R1105
R1103
Open (cut off)
R1104 (SURROUND BACK Rch)
R1106 (SURROUND Rch)
R1102 (FRONT Rch)
R1100 (CENTER)
R1101 (FRONT Lch)
R1105 (SURROUND Lch)
R1103 (SURROUND BACK Lch)
R1148
R1150
R1149
R1102
R1101
R1100
RX-V2065/HTR-6295