Assembly instructions | LK Room Temperature Control ICS.2
Description of room thermostat menus/settings
Under the room thermostat setup menu
abbreviation and its importance.
The room thermostat setup menu is accessed by holding down the SET button until
with SET. Select the required menu using the right arrow (or left arrow). Confirm with SET. Adjust the
required value and confirm with SET. The room thermostat will automatically return to normal operation
after about 1 minute. Alternatively, press SET for 5 seconds to return to normal view. Each menu option/
function is described in detail after the table.
Abbreviation
Meaning
shown in
display
SET
Setback, central tempera-
ture reduction
Holi
Holiday function
WKMD
Week mode, week program,
weekday/weekend
ECO
Economy, night setback
temperature
COMF
Comfort, normal temperature
WKEV
Week events, start/stop
times for the week program
WKPG
Week programs, enable/disable Enable week program. Option on or off. Default off.
SYSC
System clock
SYSD
System date, system cal-
endar
SENM
Sensor mode, setting
sensors
ADPT
Adaptive function on/off
BKLT
Backlight on/off
LOCK
Button lock on / off
RFST
Radio Frequency Strength
Check of signal strength
RERO
Reroute
Redirect the thermostat
FIPL
Fire Place Function
Fire place function on/off
BYPS
By-pass
RATR
Restricted allowed
temperature range
Temperature range limits
EN.33.C.152.1405
14
there are a number of abbreviations. The table below shows the
Brief explanation of menu options
Sets the required temperature for the system when the external actuation is
made via the SETBACK input on receiver 8. Preselected temperature 12 °C.
Sets the required temperature when holiday mode is enabled. Preselected
temperature 12 °C.
The unit's week program can be used for all days of the week (1-7) or for
weekday and weekend (1-5 and 6-7)
Setts the required night setback temperature. Preselected temperature 18 °C.
Sets the required normal temperature. Preselected temperature 20 °C.
Setting the start/stop times for night setback. The unit can handle two deacti-
vations and two activations per day.
Sets the system time and day of the week. 1 = Monday.
Set value applies to all units in the system.
Sets year, month and day.
Set value applies to all units in the system.
For the connected external sensor you can specify the function the external
sensor is to have. Select from only room temperature, only floor temperature,
room temperature combined with minimum floor temperature and room tem-
perature in combination with maximum floor temperature.
Activation of adaptive start times following enabled week program. Default off.
Activation of backlighting. Wireless room thermostats, default off.
Wired room thermostat, default on.
Button lock. The buttons on the unit can be locked to prevent unauthorised
users from changing the room thermostat settings.
Using this function it is possible to check the signal strength between a wire-
less room thermostat and the receiver.
Redirect the room thermostat. If necessary, it is possible to redirect/force a
wireless room thermostat to choose another route to its receiver.
The function is designed to be used when a high temperature comfort is re-
quired for the floor even though the room is heated from another source, such
as a wood burning stove.
Option on or off. Default off.
It is possible that one or more room thermostats open their circuits when the oth-
er room thermostats have closed theirs. The function is primarily designed for use
when the heat source comes from a heat pump. The function default is off.
It is possible to limit the room thermostat's adjustable temperature range.
The function can be used in an apartment building, for example, where the
residents are given the opportunity to control their room temperatures within a
temperature range of, for example, 18 to 22 °C.