LK Receiver 1 ICS.2
The LK Receiver 1 ICS.2 has 1 channel which means
only 1 LK Room Thermostat ICS.2 can be assigned/
connected to the unit.
The Receiver collects data from the room thermostat
and sends control signals to the LK Actuators. As the
communication between the receiver and actuators
is via a cable, the receiver should be placed directly
adjacent to the underfloor heating manifold.
No. Name
1
A button
2
L button
3
Button 1
4
Thermostat input
5
Actuator output
6
Power supply
7
Strain relief
8
NO/NC jumper
9
Antenna input
10
Antenna
Description
Used in combination with other buttons to enable alternative functions.
Enables/disables learning mode.
Button 1 is used to select the required channel for learning.
Thermostat input for connecting one wired room thermostat W ICS.2 (min cable size 2 x 0.5
mm
).
2
For connection of LK Actuator 24V NO (max 2 actuators per output and 5 per receiver 1).
The unit is connected to 230 V AC via the enclosed transformer.
Groove for strain relief of cables.
For adaptation of the unit to suit NO or NC actuators.
For connecting the unit's antenna.
For communication with the wireless room thermostat and the receivers when they are connect-