Steps
4. Remove electric box
a
Remove three earthing screws with screws,
pull out the indoor tube temperature sensor
with hand and then cut off the tileline with
scissors.
b
Take out the electric box shielding cover sub-
assy.
5. Remove evaporator
a
Pull out the power plug from motor and
stepping motor.
94
Procedure
temperature sensor
earthing screw
earthing screw
shielding cover sub-assy of electric box