11.2 Removal Procedure of Outdoor Unit

09K/12K
Steps
1. Remove top cover
Remove the screws connecting top cover, left and
right side plate, as well as panel, to remove the top
cover.
2. Remove handle and valve cover
Remove the screws connecting handle and right side
plate, to remove the handle.Remove the screw fixing
valve cover, to remove the cover.
3. Remove panel and grille
Remove the screws fixing panel, to remove the panel.
Remove the screws connecting panel grille and panel,
loosen the clamp, to remove the panel grille.
Installation and Maintenance
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Procedure
top cover
handle
valve cover
panel
grille