Refrigerant System Diagram - Gree GWH12UB-K3DNA4F Service Manual

Hide thumbs Also See for GWH12UB-K3DNA4F:
Table of Contents

Advertisement

Service Manual

4. Refrigerant System Diagram

INDOOR UNIT
HEAT
EXCHANGE
(EVAPORATOR)
Connection pipe specification:
Liquid : 1/4" (6mm) Gas : 1/2" (16mm)
Technical Information
GAS SIDE
3-WAY VALVE
Discharge
Suction
COMPRESSOR
LIQUID SIDE
Electron
Strainer
2-WAY VALVE
expansion
valve
OUTDOOR UNIT
4-Way valve
Accumlator
HEAT
EXCHANGE
(CONDENSER)
Intercooler
Strainer
Strainer
Capillary
Strainer
COOLING
HEATING