Gree GWH12UB-K3DNA4F Service Manual page 54

Hide thumbs Also See for GWH12UB-K3DNA4F:
Table of Contents

Advertisement

Service Manual
Malfunction
Dual-8
NO.
Name
Code
Display
Decrease
frequency
19
due to
F9
high air
discharge
Limit/
decrease
20
frequency
FH
due to
antifreezing
Voltage for
21
DC bus-bar
PH
is too high
Voltage of
22
DC bus-bar
PL
is too low
Compressor
Min
23
P0
frequence in
test state
Compresso r
rated
24
P1
frequenc e in
test state
Compressor
maximum
25
P2
frequence in
test state
Installation and Maintenance
Display Method of Indoor Unit
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s)
Operation
Cool
Heating
Indicator
Indicator
Indicator
Display Method of Outdoor
Unit
Indicator has 3 kinds of
display status and during
blinking, ON 0.5s and OFF
0.5s
Yellow
Red
Green
Indicator
Indicator
Indicator
All loads operate normally,
OFF 1S
while
and
blink
operation frequency for
twice
compressor is decreased
OFF 1S
All loads operate normally,
and
while operation frequency for
blink
compressor is decreased
4 times
During cooling and drying
operation, compressor will stop
OFF 1S
while indoor fan will operate;
and
blink
During heating operation, the
13 times
complete unit will stop
operation.
During cooling and drying
OFF 1S
operation, compressor will stop
and
while indoor fan will operate;
blink
During heating operation, the
12 times
complete unit will stop
A/C status
Possible Causes
Overload or temperature is too
high;
Malfunction of electric expansion
valve (EKV)
Poor air-return in indoor unit or fan
speed is too low
1. Measure the voltage of position
L and N on wiring board (XT), if the
voltage is higher than 265VAC, turn
on the unit after the supply voltage
is increased to the normal range.
2.If the AC input is normal,
measure the voltage of electrolytic
capacitor C on control panel (AP1),
if its normal, theres malfunction
for the circuit, please replace the
control panel (AP1)
1. Measure the voltage of position
L and N on wiring board (XT), if the
voltage is higher than 150VAC,
turn on the unit after the supply
voltage is increased to the normal
range.
2.If the AC input is normal,
measure the voltage of electrolytic
capacitor C on control panel (AP1),
if its normal, theres malfunction
for the circuit, please replace the
control panel (AP1)
Showing during min. cooling or
min. heating test
Showing during nominal cooling or
nominal heating test
Showing during max. cooling or
max. heating test
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh09ub-k3dna4fGwh18uc-k3dna4f

Table of Contents