Setting the time program
7.
to confirm.
d
8.
/
to select the required part of the week or
|
~
day.
9.
to confirm.
d
10.
/
for selecting the time phase
|
~
.
$
11.
to confirm.
d
12.
/
to set the start time.
|
~
13.
to confirm.
d
14.
/
to set the end time.
|
~

Deleting time phases

To delete a time phase, press the following keys:
1. Proceed as described in points 1 to 12 of chapter
"Setting a time program" from page 28.
2.
until the end point of the selected time phase
d
is displayed.
3.
/
until, for the end point, "- - : - -" is displayed.
|
~
Time program
0
2
4
6
8 10 12 14 16 18 20 22 24
? - -:- - - - -:- -
u
§ - -:- - - - -:- -
u
Change with
Fig.30

Setting the heating curve

In the "Automatic" operating program, the control unit
automatically determines the average set temperature
of the heating water buffer cylinder. It takes into
account the selected heating curve and the outside
temperature.
Press the following keys:
1.
for "Extended menu".
å
2.
/
to select "Buffer".
|
~
3.
to confirm.
d
(cont.)
,
,
or
!
?
§
Mo-Su
---
---
(
Heating water buffer cylinder
15.
to confirm.
d
Example shown:
Time program for Monday to Friday ("Mo-Fr")
Time phase
!
:
from 04:30 to 08:30 h
Time phase
:
?
from 16:30 to 23:00 h
!
?
Mo-Fr
0 2 4 6 8 10 12 14 16 18 20 22 24
I
1
04:30 - 08:30
Std
I
2
16:30 - 23:00
Std
Select with
Fig.29
4.
to confirm.
d
5.
until the standard display is shown.
ä
4.
/
for "Heating curve".
|
~
5.
to confirm.
d
6.
/
for "Slope"
|
~
or "Level".
7.
to confirm.
d