Trouble Shooting; Specifications - Tennant 3000 Operator And Parts Manual

Portable dry vacuum
Hide thumbs Also See for 3000:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLE SHOOTING

PROBLEM
Vacuum motor will not operate.
Poor vacuum suction.

SPECIFICATIONS

MODEL
LENGTH
WIDTH
HEIGHT
WEIGHT
VACUUM MOTOR
VACUUM BAG CAPACITY
POWER CORD LENGTH
DECIBEL RATING AT OPERATOR'S EAR,
INDOORS ON CARPET
Tennant 3000/3040/3050 (06- -03)
CAUSE
Power switch in off position.
Faulty power cord.
Tripped building circuit breaker.
Overheated motor.
Faulty power switch.
Loose wiring.
Loose vacuum hose or attachment
tool connection.
Clogged vacuum hose or attachment
tool.
Full vacuum bag.
Air leak in hose.
Clogged secondary filter or foam filter.
Air leak at bag compartment lid.
Loose bag compartment lid.
Home
Find... Go To..
SOLUTION
Turn on machine.
Contact Service Center.
Reset circuit breaker.
Let motor cool, determine cause.
Contact Service Center.
Contact Service Center.
Tighten connections.
Remove clogged debris.
Empty vacuum bag.
Replace hose.
Remove filters and clean. Do not
operate machine without filters in place.
Replace lid gasket.
Close lid tightly.
3000/3040/3050
210mm (8.25 in)
190mm (7.5 in)
600mm (2 ft)
5.5 Kg (12 lbs)
120V, 1.7hp, 2--stage, 10A, 1200W (3040 & 3050)
120V, 1.15hp, 2--stage, 7.5A, 900W (3000)
220V/230V/240V, 1.3kW, 2--stage, 5A, 1150W (3050)
4.75 L (4.3 qts)
15m (50 ft), Gauge--16/3 (120V) (3040 & 3050)
15m (50 ft), Gauge--18/3 (120V) (3000)
15m (50 ft), Gauge--18/3 (220V/230V/240V) (3050)
<75dB(A)
OPERATION
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

30406077573050607751609694609209

Table of Contents