PRODUCT DESIGN
PREFERRED
ACCEPTABLE
22
TRANSITION NO LESS
THAN 45 DEGREES TO
HORIZONTAL PLANE TO
AVOID CREATING A WATER
TRAP IN VENT PIPING.
NO TRANSITION ON
HORIZONTAL PLANE,
THIS CREATES A
WATER TRAP AND
RESTRICTS FLUE
GASES
*MVM97/*CVM97 Direct Vent (2 - Pipe) and Non-Direct Vent (1- Pipe)
Maximum Allowable Length of Vent/Flue Pipe & Combustion Air Pipe (ft)
Unit
Pipe Size
Input
(4)
(in.)
0
1
(Btu)
2
60,000
250
245
or 2 1/2
2
80,000
250
245
or 2 1/2
80,000
3
250
243
2
100,000
90
85
or 2 1/2
100,000
3
250
243
2
120,000
75
70
or 2 1/2
120,000
3
220
213
1) Maximum allowable limits listed on individual lengths for inlet and
flue and NOT a combination.
2) Minimum requirement for each vent pipe is five (5) feet in length
and one elbow/tee.
3) Tee used in the vent/flue termination must be included when de-
termining the number of elbows in the piping system.
4) 2 1/2" or 3" diameter pipe can be used in place of 2" diameter
pipe.
5) Increased Clearance Configurations using (2) 45 deg. Elbows should
be considered equivalent to one 90 deg. elbow.
6) One 90° elbow should be secured to the combustion air intake
connection.
(3) (5)
Number of Elbows
2
3
4
5
6
240
235
230
225
220
215
240
235
230
225
220
215
236
229
222
215
208
201
80
75
70
65
60
55
236
229
222
215
208
201
65
60
55
50
45
40
206
199
192
185
178
171
(6)
(1) (2)
7
8
210
210
194
50
194
35
164