OPERATION
CUT USING TIN SNIPS
PRESS OUT BY HAND
CUT FOUR CORNERS
AFTER REMOVING SHEET
METAL
SCRIBE LINES OUTLINING
DUCT FLANGES
Duct Flange Cut Outs
When a cooling coil is installed with the furnace, it must be
installed in the supply air to avoid condensation from
occuring in the heat exchanger.
When the furnace is installed without a cooling coil, it is recom-
mended that a removable access panel be provided in the out-
let air duct. This opening shall be accessible when the furnace
is installed and shall be of such a size that the heat exchanger
can be viewed for visual light inspection or such that a sam-
pling probe can be inserted into the airstream. The access
panel must be made to prevent air leaks when the furnace is in
operation.
When the furnace is heating, the temperature of the return air
entering the furnace must be between 55°F and 100°F.
F
- R
T
S
B
I
T
R
ILTERS
EAD
HIS
ECTION
EFORE
NSTALLING
HE
ETURN
A
D
IR
UCT WORK
Filters must be used with this furnace. Discuss filter mainte-
nance with the building owner. Filters do not ship with this
furnace, but must be provided, sized and installed externally by
the installer. Filters must comply with UL900 or CAN/ULCS111
standards. If the furnace is installed without filters, the war-
ranty will be voided.
On upflow units, guide dimples locate the side return cutout
locations. Use a straight edge to scribe lines connecting the
dimples. Cut out the opening on these lines. NOTE: An under-
sized opening will cause reduced airflow.