Power Supply Indicators
Only redundant Power Supply Units (PSUs) have a LED indicator to show the power supply status.
Status lights provide indications as follows:
Not lit: AC power is not connected.
Green: In standby mode, a green light indicates that a valid AC source is connected to the power supply and that
the power supply is operational. When the system is on, a green light also indicates that the power supply is
providing DC power to the system.
Amber: Indicates a problem with the power supply.
Alternating green and amber: When hot-adding a power supply, this indicates that the power supply is
mismatched with the other power supply (e.g., a high output 1100-W power supply and a 750-W power supply are
installed in the same system). Replace the power supply that has the flashing indicator with a power supply that
matches the capacity of the other installed power supply.

4.5 Side Views and Features

PowerEdge R510 Technical Guide

Figure 11. Redundant PSU

Figure 12. Left Side View

Figure 13. Right Side View