About the Generic Terms and Abbreviations

Generic Term/Abbreviation
GPPW
ACPU
QnACPU
QCPU (A mode)
QCPU (Q mode)
Master station
Local station
Remote I/O station
Remote device station
Remote station
Intelligent device station
Master module
SB
SW
RX
RY
RWw
RWr
Unless otherwise specified, the following generic terms and abbreviations are used in
this manual to describe Type AJ65SBT-64AD analog-digital converter module.
Abbreviation for the SW4D5C-GPPW-E or later GPP function software.
Generic term for A0J2CPU, A0J2HCPU, A2CPU, A2CPU-S1, A3CPU, A1SCPU,
A1SCPU-S1, A1SCPUC-24-R2, A1SHCPU, A1SJCPU, A1SJCPU-S3, A1SJHCPU,
A1NCPU, A2NCPU, A2NCPU-S1, A3NCPU, A3MCPU, A3HCPU, A2SCPU, A2SCPU-
S1, A2SHCPU, A2SHCPU-S1, A2ACPU, A2ACPU-S1, A3ACPU, A2UCPU, A2UCPU-
S1, A2ASCPU, A2ASCPU-S1, A2ASCPU-S30, A2USHCPU-S1, A3UCPU, A4UCPU
Generic term for Q2ACPU, Q2ACPU-S1, Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU,
Q2ASHCPU-S1, Q3ACPU, Q4ACPU, Q4ARCPU
Generic term for Q02CPU-A, Q02HCPU-A, Q06HCPU-A
Generic term for Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU
Station that controls the data link system.
One master station is required for each system.
Station having a PLC CPU and the ability to communicate with the master and other
local stations.
Remote station that handles bit unit data only. (Performs input and output with external
devices.) (AJ65BTB1-16D, AJ65SBTB1-16D)
Remote station that handles bit unit and word unit data only. (Performs input and output
with external devices, and analog data exchange.)
Generic term for remote I/O station and remote device station.
(Controlled by the master station)
Station that can perform transient transmission, such as the AJ65BT-R2 (including local
stations).
Generic term for QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11, and
A1SJ61QBT11 when they are used as master stations.
Link special relay (for CC-Link)
Bit unit information that indicates the module operating status and data link status of the
master station/local station. (Expressed as SB for convenience)
Link special register (for CC-Link)
16 bit unit information that indicates the module operating status and data link status of
the master station/local station. (Expressed as SW for convenience)
Remote input (for CC-Link)
Information entered in bit units from the remote station to the master station. (Expressed
as RX for convenience)
Remote output (for CC-Link)
Information output in bit units from the master station to the remote station. (Expressed
as RY for convenience)
Remote register (Write area for CC-Link)
Information output in 16-bit units from the master station to the remote device station.
(Expressed as RWw for convenience)
Remote register (Read area for CC-Link)
Information entered in 16-bit units from the remote device station to the master station.
(Expressed as RWr for convenience)
Description
A - 8