  • Page 1 Instructions for the installation and advice for the maintenance EF/60 4G AI - E/70 5G AI TR Manual of instructions EF/60 4G AI - E/70 5G AI TR COD. 01001AU – 18.06.2002...
  • Page 2 DESCRIPTION OF THE HOT PLATES MODEL : 40220501 MODEL : 40220050 1 Ultra rapid burner of 11.9 MJ/h 15.0 MJ/h 2 Rapid gas burner of 10.8 MJ/h 12.0 MJ/h 3 Semirapid gas burner of 6.3 MJ/h 7.3 MJ/h 4 Auxiliary gas burner 3.6 MJ/h 4.2 MJ/h 6 Enamelled steel pan support 2F...
  • Page 3 1) BURNERS A diagram is screen-printed above each knob on the front panel. This diagram indicates to which burner the knob in question corresponds. After having opened the gas mains or gas bottle tap, light the burners as described below: −...
  • Page 4 Never use aerosols near the appliance when it is operating. If the built-in hot plate has a lid, any spilt food should be immediately removed from this before it is opened. If the appliance has a glass lid, this could shatter when the hot plate becomes hot. Always switch off all the burners before closing the lid.
  • Page 5 Notes: Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated by keeping the natural air vents clear (fig. 3) and by activating the mechanical aeration device (suction hood or electric fan fig.
  • Page 6 CLEANING IMPORTANT: Always disconnect the appliance from the gas and electricity mains before carrying out any cleaning operation. 2) HOT PLATE Periodically wash the hot plate, the enamelled steel pan support, the enamelled burner caps “C” and the burner heads “T” (see fig. 6) with lukewarm soapy water. Following this, all parts should be thoroughly rinsed and dried.
  • Page 7: Installation

    INSTALLATION TECHNICAL INFORMATION FOR THE INSTALLER This appliance must be installed only authorised personnel and in accordance with the regulations of the Gas Installation Code AS5601/AG601 and Electricity authorities. The wall and bench surfaces must be capable of sustaining temperatures of 75 degrees Celsius.
  • Page 8 INSTALLATION FIG. 7 FIG. 8 FIG. 9 FIG. 10...
  • Page 9: Gas Connection

    INSTALLATION 5) GAS CONNECTION The gas connection is located in the rear and on the underside of the appliance 100 mm from the right hand side. Natural Gas Both Natural and Town Gas installations require the connection of a gas regulator at the appliance.
  • Page 10 ADJUSTMENTS Always disconnect the appliance from the electricity main before making any adjustments. All seals must be replaced by the technician at the end of any adjustments or regulations. Our burners do not require primary air adjustment. a) Data Label The Data Label is located on the underside of the hotplate.
  • Page 11 CONVERSIONS 8) U-LPG to Natural Gas conversion procedure Appliance models: Gas stainless steel hotplate models: 4 Burners 5 Burners 1. Remove each burner cap and burner skirt. 2. Remove the U-LPG main injector with a 7 mm/VF tube spanner and replace with the appropriate size Natural Gas injector for each burner.
  • Page 12 CONVERSIONS 9) Natural Gas to Universal LPG conversion procedure Appliance models: Gas stainless steel hotplate models: 4 Burners 5 Burners 1. Remove each burner cap and burner skirt. 2. Remove the Natural Gas main injector with a 7 mm/VF tube spanner and replace with the appropriate size U-LPG main injector for each burner.
  • Page 13 CONVERSIONS BURNER ARRANGEMENT ON THE HOT PLATE TABLE BURNERS NORMAL INJECTOR NOMINAL PRESSURE DIAMETER HEAT INPUT (MJ/h) N° DESCRIPTION (kPa) (1/100 mm) MAX. PROPANE 2.75 11.9 ULTRA RAPID NATURAL 1.00 15.0 PROPANE 2.75 10.8 RAPID NATURAL 1.00 12.0 PROPANE 2.75 SEMIRAPID NATURAL 1.00...
  • Page 14: Components Replacement

    SERVICING WARNING: Servicing should be carried out only by authorised personnel. 10) COMPONENTS REPLACEMENT NOTE: BEFORE ANY MAINTENANCE REQUIRING REPLACEMENT OF A COMPONENT IS UNDERTAKEN ENSURE THAT THE ELECTRICAL LEAD HAS BEEN ISOLATED AND REMOVED FROM THE POWER POINT. To replace the components fit inside the hob is necessary to take off the pan supports and the burners from the upper part of the working table, then unscrew the burner fixing screws “V”...
  • Page 15 SERVICING CABLE TYPES AND SECTIONS TYPE OF TYPE OF SINGLE - PHASE HOT PLATE CABLE POWER SUPPLY Gas hot plate H05 RR - F Section 3 X 0.75 mm ATTENTION!!! If the power supply cable is replaced, the installer should leave the ground wire longer than the phase conductors (fig.
  • Page 16: Technical Assistance And Spare Parts

    TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory, this appliance will have been tested and regulated by expert and specialized personnel in order to guarantee the best performances. Any repairs or adjustments which may be subsequently required may only be carried out by qualified personnel with the utmost care and attention.