Programming Labels; Keypad Display Symbols; Changing The Buzzer Level - DSC PK5500/RFK5500 Installation Instructions Manual

Power series
Table of Contents

Advertisement

Available languages

Available languages

Programming Labels

(PK5500\RFK5500 Only)
1. Enter keypad programming by pressing [][8][Installer Code][].
Enter the 3-digit section number for the label to be programmed.
2. Use the arrow keys (<>) to move the underline bar underneath
the letter to be changed.
3. Press the number keys [1] to [9] corresponding to the letter you
require. The first time you press the number the first letter will
appear. Pressing the number key again will display the next letter.
[1] - A, B, C, 1 [4] - J, K, L, 4 [7] - S, T, U, 7 [0] - Space
[2] - D, E, F, 2 [5] - M, N, O, 5 [8] - V, W, X, 8
[3] - G, H, I, 3 [6] - P, Q, R, 6 [9] - Y, Z, 9,0
4. When the required letter or number is displayed use the arrow keys
(<>) to scroll to the next letter.
5. When you are finished programming the Zone Label, press the [
key, scroll to "Save," then press [
].
6. Continue from Step 2 until all Labels are programmed.
ASCII Characters
Changing Brightness/Contrast
LCD Keypads
1. Press [][6][Master code].
2. Use the [<][>] keys to scroll to either Brightness Control or Con-
trast Control.
3. Press [] to select the setting you want to adjust.
4. a) 'Brightness Control': There are multiple backlighting levels. Use
the [<][>] keys to scroll to the desired level.
b) 'Contrast Control': There are 10 different display contrast levels.
Use the [<][>] keys to scroll to the desired contrast level.
5. To exit, press [#].
LED/ICON Keypads
1. Press [][6][Master Code].
2. Use the [>] key to move through the 4 different backlighting levels.
3. The level is automatically saved when you press [#] to exit.

Changing the Buzzer Level

LCD Keypads
1. Press [][6][Master Code].
2. Use the [<][>] keys to scroll to Buzzer Control.
3. There are 21 different levels, use the [<][>] keys to scroll to the
desired level.
4. To exit, press [#].
LED/ICON Keypads
1. Press [][6][Master Code].
2. Use the [<] key to move through the 21 different buzzer levels.
3. The level is automatically saved when you press [#] to exit.
]
Broadcasting Door Chime
All door chime programming is done per keypad. If more than one
keypad is present on the system, door chime programmed at one
keypad can be broadcast to all other keypads. Perform the following
procedure in order to broadcast door chime:
Step 1 - Program one keypad completely.
Step 2 - Make sure all keypads are connected to the Keybus.
Step 3 - Enter keypad programming by pressing [][8][Installer
Code][], then enter section [994] at the keypad that was pro-
grammed. The keypad will now broadcast all the door chime
information programmed to all the other keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.

Keypad Display Symbols

9
8
2
1
12
7
11
10
Fire – Indicates that there are fire alarms in memory.
1
2 Memory – Indicates that there are alarms in memory.
Ready Light (green) – If the Ready light is on, the system is
3
ready for arming.
4 Armed Light (red) – If the Armed light is on, the system has
been armed successfully.
5 System Trouble – Indicates that a system trouble is active.
6 AC – Indicates that AC is present at the main panel.
Program – Indicates that the system is in Installer's Program-
7
ming, or the keypad is busy.
Bypass – Indicates that there are zones automatically or man-
8
ually bypassed.
9 For Future Use
10 Arm Mode – Indicates the mode the panel is armed in.
Stay – Indicates that the panel is armed in the Stay Mode. It
will turn on at the beginning of the Exit Delay
Away – Indicates that the panel is armed in the Away Mode.
It will turn on at the beginning of the Exit Delay
Chime – This icon turns on when Door Chime is enabled on the
11
system and will turn off when Door Chime is disabled.
Open – When zones are opened, this icon will turn on, and 7
12
segment displays 1 and 2 will scroll through the open zones.
2
1
3
4
5
6
8
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pk5501/rfk5501Pk5508/rfk5508Pk5516/rfk5516

Table of Contents