Download Print this page

Troubleshooting; How To Use; Safety Information - Smeg SA950CXA Instruction Manual

Hide thumbs Also See for SA950CXA:

Advertisement

Troubleshooting

If any problem occurs, please detach the plug from the
socket and contact the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
Problem
Cause
Light on, but motor
The outlet valve is blocked
does not work
The capacitor has failed
The control switch has
failed
Light
does
not
No power supply
work, motor does
not work
Fuse has blown
Vibration
The propeller is damaged or
unbalanced
The hood is not installed
correctly
Insufficient suction
The distance between the
effect
hood and the cooker is too
far
The filters are saturated
Solution
Detach flue and duct then turn
on the hood to check if the
valve opens
Call for technical service
Call for technical service
Plug another appliance into the
socket to confirm there is
power supply
Check the fuse or reset the
circuit breaker
Call for technical service
Review
the
installation
instructions
&
check
the
installation again for loose
screws, brackets or connections
Check that the distance is
between 650mm to 750mm for
a gas appliance and 600mm for
electric hobs
Clean the filters from grease
residue
and
replace
after
drying.
Contents
Introduction...............................1
Features....................................2
Installation.................................2
Charcoal filter (optional).............4

How To Use...............................5

Safety Information......................6

Troubleshooting.........................7
Electrical Diagram.....................8
Specifications............................8
Cleaning & Maintenance.............9

Advertisement