  • Page 1 User Manual Phenom Dual Motor Upright Vacuum...
  • Page 2: Introduction

    The operating manual contains all the The Minuteman Phenom may only be important information you need to operated, serviced and repaired by operate, maintain and service the personnel who are familiar with the machine.
  • Page 3: Information On The Warranty

    Any damage is the responsibility of the manufacturer is not deemed liable for maintenance. Maintenance work must delivery carrier who should be notified any damage resulting from be performed by authorized Minuteman immediately. unauthorized modifications to the service centers and confirmed in the machine.
  • Page 4: Table Of Contents

    Technical Data ..18 Behavior following faults or Minuteman Limited accidents ....9 Warranty ....30 Disposing of the machine .
  • Page 5: Safety Information

    Safety Information Safety Information Safety and warning symbols All sections related to personal safety, safety of the machine and environmental protection are assigned the following symbols throughout the operating manual: Symbol Damage to ... Definition Read operating manual persons Safety information to prevent hazardous situations or property caused by a failure to follow instructions or prescribed working procedures accurately or at all.
  • Page 6: General Information

    • The warning labels attached to the manipulation can have fatal the information during work. equipment provide important consequences and, in all cases, • The Minuteman Phenom may only information concerning safe annuls all rights to claims under the be operated, serviced and repaired operation.
  • Page 7 • It is forbidden to use the machine in be caused. • Never leave the Minuteman Phenom potentially explosive atmospheres. • Do not allow the rotating brushes to unattended when it is switched on.
  • Page 8: Maintenance Information

    Switch parts, switch the machine off and Minuteman service center or by an the machine off immediately and disconnect the power plug from the appropriately qualified electrician. disconnect the power plug from the power socket.
  • Page 9: Environmental Protection

    • Clean the dust filter outdoors and • Inform colleagues, superiors, and recycling, please contact your wear personal protective equipment emergency services or others authorized Minuteman dealer where when doing so! Do not inhale the according to the type of fault. you purchased the machine. dust.
  • Page 10: Labels On The Machine

    Safety Information Labels on the machine The following safety and warning labels are attached to the machine where easily legible. Missing or illegible labels must be replaced immediately. Company logo (Fig. 1/1) Indication of desinfecting effect: The machine combats bacteria, fungi and dust mites (Fig.
  • Page 11 Safety Information Rating plate (Fig. 1/3) Assembly notes for electrical brush Safety information: Do not use the The rating plate is on the rear side of the (Fig. 1/5) machine outdoors or on wet machine. surfaces! (Fig. 1/6) Brush head rating plate (Fig. 1/4) The rating plate is on the rear side of the brush head.
  • Page 12: Operation

    Operation Operation Assembly For transportation reasons, the shaft, suction hose and brush head are not assembled. Proceed as follows to assemble these parts: 1. Insert the shaft (Fig. 2/3) in the opening at the top of the vacuum cleaner and press down until the locking mechanism (Fig.
  • Page 13: Operation

    • through high area coverage, thanks blow). thorough cleaning. It is gentle to to the broad working width of the 1. Switch the Minuteman Phenom on carpets, so extending the service life of brush base and optimum using the On/Off switch (Fig. 6/5) textile flooring.
  • Page 14: Working With The Hand-Held Suction Hose

    Operation Fig. 4 Working with the hand-held suction hose The Minuteman Phenom can also be used to clean areas which are difficult to Fig. 5 access, e.g. to clean corners or confined spaces. Set the shaft to its The suction hose can be vertical position.
  • Page 15: Function Faults

    Operation Function faults Fault Cause Solution The Minuteman Phenom does not No voltage Check the fuse , cable, power socket switch on and power plug The brush head does not work, Set the shaft to its vertical position Set the shaft to its working position...
  • Page 16: Operating And Indicator Elements

    Operating and Indicator Elements Operating and Indicator Elements 1 Nozzle 2 Suction hose 3 Handle 4 Shaft 5 On/Off switch 6 Change filter indicator 7 Power plug with cable 8 Carrying handle 9 Cover latch 10 Control lamps for brush pressure 11 Bearing, brush roller 12 Rotary knob for brush height adjustment...
  • Page 17 Locking device (Fig. 6/13) overloaded and switches off Change filter indicator (Fig. 6/6) It serves to set the Minuteman Phenom automatically. The brush height must It lights up when the filter bag needs to vertical, e.g. for transportation or then be increased.
  • Page 18: Technical Data

    Technical Data Technical Data Dimensions Width Height Depth Length of hand-held suction hose (extended/retracted) 240/63 Working width Brush roller Weight Total weight Electrical installation Mains power supply V/Hz 230/50 Type of current Alternating current (AC) Total nominal power Protection class Brush head No.
  • Page 19 Technical Data Aspirating engine Output Air flow rate l/sec Fan vacuum mm WS 2000 Noise emission value Sound pressure level in accordance with DIN 45635 dB (A) Standard accessories Nozzle Rotating brush Special equipment Electronic control unit Washable fabric sack HEPA filter, Class S (for clean rooms) Activated carbon filter Fan accessories...
  • Page 20 Technical Data Device features: Area of use: For the dry cleaning of carpets inside industrial buildings (e.g. plants, hotels, hospitals, residential homes, cleaning businesses) 5-stage microfilter system (combats viruses, bacteria, fungi and microparasites) Approved for use in hospitals Volume filter bags Exchange of brush roller with V-bristle arrangement without tools Control lamp for changing the filter bags Automatic device switch-off when shaft is vertical...
  • Page 21: Maintenance And Service

    (Fig. 6/6) lights up. maintenance may only be completed by personnel who are correspond-ingly qualified and trained. Please contact your nearest Minuteman service center or Minuteman authorized dealer. Failure to observe this annuls any rights to claims under the terms of guarantee in respect of resulting damage or consequential damage.
  • Page 22: Changing The Paper Filter Bag

    (Fig. 7/4) and remove it from the filter compartment (Fig. 7/1). 3. Insert a new paper filter bag (Fig. 7/3). Never operate the Minuteman Phenom without a paper filter bag. Only use original paper filter bags:...
  • Page 23: Cleaning The Motor Protection Filter

    Maintenance and Service Cleaning the motor protection filter The motor protection filter, underneath the filter compartment, must be checked regularly for accumulation of dirt and, when necessary, tapped clean or replaced by a new one. Proceed as follows to replace the motor protection filter: 1.
  • Page 24: Changing The Microfilter

    Maintenance and Service Changing the microfilter This filter should be changed with each fifth paper filter bag change. 1. Press the cover latch (Fig. 9/2) and remove the microfilter cover (Fig. 9/1). 2. Remove the plastic grid (Fig. 9/3) and replace the microfilter (Fig.
  • Page 25: Changing The Brush Roller

    The brush roller can be removed in just 2 Base plate a few steps: 3 Brush shaft 4 Bearing 1. Switch the Minuteman Phenom off 5 Brush roller and disconnect the power plug. 6 Brush head 2. Remove the brush head (Fig. 10/6).
  • Page 26 Notes...
  • Page 27 Notes...
  • Page 28: Ce Declaration

    CE Declaration...
  • Page 29 CE Declaration Cont’d.
  • Page 30: Warranty

    Minuteman International, Inc. warrants to the original purchaser/user that the product is free from defects in workmanship and materials under normal use. Minuteman will, at its option, repair or replace without charge, parts that fail under normal use and service when operated and maintained in accordance with the applicable operation and instruction manuals. All warranty claims must be submitted through and approved by factory authorized repair stations.
  • Page 31: Minuteman International Made Simple Commercial Limited Warranty

    Minuteman International Made Simple Commercial Limited Warranty Cord Electric Group: Three years parts, two years labor, ninety days travel (Not to exceed two hours) Exceptions………. Model Parts Labor Poly Travel Port A Scrub 1 yr 6 months 10 yrs MPV 13 1 yr MPV 14 &...
  • Page 32 Minuteman International Inc. · 14N845 U.S. Route 20 · Pingree Grove, Illinois 60140 · U.S.A. Phone: 800-323-9420 · Fax 800-422-6933 www.minutemanintl.com A Member of the Hako Group...

Table of Contents