Section 8: Service; Troubleshooting - Grizzly G0690 Owner's Manual

10" cabinet table saw w/riving knife
Hide thumbs Also See for G0690:
Table of Contents

Advertisement

Troubleshooting

SECTION 8: SERVICE

Review the troubleshooting and procedures in this section if a problem develops with your machine. If you
need replacement parts or additional help with a procedure, call our Technical Support. Note: Please gather
the serial number and manufacture date of your machine before calling.
Symptom
Possible Cause
Machine does not
1. Locking pin installed.
start or a breaker
2. Blown fuse.
trips.
3. Power supply switched OFF or at fault.
4. Plug/receptacle at fault/wired wrong.
5. Motor connection wired wrong.
6. Wall circuit breaker tripped.
7. Wiring open/has high resistance.
8. Motor ON/OFF switch at fault.
9. Start capacitor at fault.
10. Motor at fault.
Machine stalls or is
1. Feed rate/cutting speed too fast.
underpowered.
2. Workpiece material unsuitable for machine.
3. Workpiece crooked; fence mis-adjusted.
4. Machine undersized for task.
5. Run capacitor at fault.
6. Belt slipping.
7. Motor wired incorrectly.
8. Plug/receptacle at fault.
9. Pulley/sprocket slipping on shaft.
10. Motor bearings at fault.
11. Contactor not energized/has poor contacts.
12. Motor overheated.
13. Motor at fault.
Machine
has
1. Motor or component loose.
vibration or noisy
operation.
2. Blade at fault.
3. Belts worn or loose.
4. Pulley loose.
5. Motor mount loose/broken.
6. Machine incorrectly mounted.
7. Arbor pulley loose.
8. Motor fan rubbing on fan cover.
9. Arbor bearings at fault.
10. Motor bearings at fault.
Model G0690/G0691 (Mfd. 6/15+)
Troubleshooting
Possible Solution
1. Remove locking pin from ON button.
2. Replace fuse/ensure no shorts.
3. Ensure power supply is on/has correct voltage.
4. Test for good contacts; correct the wiring.
5. Correct motor wiring connections.
6. Ensure circuit size is correct/replace weak breaker.
7. Check/fix broken, disconnected, or corroded wires.
8. Replace switch.
9. Test/replace if faulty.
10. Test/repair/replace.
1. Decrease feed rate/cutting speed.
2. Only cut wood/ensure moisture is below 20%.
3. Straighten or replace workpiece/adjust fence.
4. Use correct blade/reduce feed rate or depth of cut.
5. Test/repair/replace.
6. Tension/replace belt (Page 73).
7. Wire motor correctly.
8. Test for good contacts/correct wiring.
9. Replace loose pulley/shaft.
10. Test/repair/replace.
11. Test all legs for power/replace if faulty.
12. Clean motor, let cool, and reduce workload.
13. Test/repair/replace.
1. Inspect/replace damaged bolts/nuts, and re-tighten
with thread locking fluid.
2. Replace warped/bent blade; resharpen dull blade.
3. Tension/replace belts (Page 73).
4. Realign/replace shaft, pulley, setscrew, and key.
5. Tighten/replace.
6. Tighten mounting bolts; relocate/shim machine.
7. Retighten/replace arbor pulley.
8. Fix/replace fan cover; replace loose/damaged fan.
9. Replace arbor housing bearings; replace arbor.
10. Test by rotating shaft; grinding/loose shaft requires
bearing replacement.
-63-

Advertisement

Table of Contents
loading

This manual is also suitable for:

G0691