Maintaining maximum cutting capacity
Unplug the
tool
before any adjustment
is
attempted.
This
tool
is
factory adjusted
to pro-
vide the max. cutting capacity for a 255 mm
(IO")
saw blade. When the diameter of the
blade has been reduced due to sharpening, adjust the lower limit position of the blade as
follows:
Push the carriage toward the guide fence fully and lower the handle completely. Use the
socket wrench to turn the adjusting bolt until the periphery
of
the blade extends slightly
below the top surface
of
the turn base at the point where the front face of the guide fence
meets the top surface of the turn base. With the tool unplugged, rotate the blade by hand
while holding the handle all the away down to be sure that the blade does not contact any
part of the lower base. Re-adjust slightly, if necessary
I
I
L T u r n
base
Periphery
Top
surface
of turn
base
- - _ _ - /
Guide fence
'
CAUTION:
After installing a new blade, always be sure that the blade does not contact any part of
the lower base when the handle is lowered completely. Always do this with the tool
unplugged
Positioning
for
adjusting the miter angle
Loosen the grip by turning counterclock-
wise. Turn the turn base while pressing
down the lock pin. When you have moved
the grip to the position where the pointer
indicates the desired angle on the miter
scale, securely tighten the grip clockwise.
L
G
r
i
p
Miter scale
CAUTl ON :
*When turning the turn base, be sure to raise the handle fully.
*After changing the miter angle, always secure the turn base by tightening the grip firmly.