3 7 63 1515 0
ADJUSTMENT PROCESURE
OUTPUT OFFSET VOLTAGE
Conditions: Non load, no signal.
1. Set the voltage at L-ch speaker terminal to
0mV +/- 10mVDC by adjusting R513 of
BAAF-0249.
Same as R514 (R-ch).
2. After 2 minutes, set the voltage at speaker
terminal to 0mV +/- 10mV again.