34
2. Twist the steam nozzle (6d) anticlock-
wise and remove it.
3. Remove the frothing tube (6c).
6c
4. Clean the individual parts with a
detergent solution and a soft brush. If
necessary, soak in a warm detergent
solution. Clean the air hole (6e)
thoroughly.
5. Rinse all parts with clean water and dry.
6. Fit the steam nozzle (6d) and frothing
tube (6c) back into the metal sleeve.
6c
1
7. Twist the steam nozzle clockwise until
the marks are aligned.
Robert Bosch Hausgeräte GmbH
TES55236RU.indb 34
1
6d
2
6e
6d
2
8. Attach the milk frother to the steam
valve. Check that the red mark on the
steam valve is covered.
¡
Risk of scalding!
Only use the appliance when the milk
frother (6) is completely assembled and
fi tted.

Cleaning the brewing unit

Clean the brewing unit regularly.
To pre-clean the brewing unit automatically:
e
1. Select
by turning the rotary knob (14).
2. Place an empty glass under outlet (7).
3. Press the start button (10).
The appliance rinses.
In addition to the automatic cleaning pro-
gramme, the brewing unit (5a) should be
removed regularly for cleaning. (See fi gure
E at the start of the operating instructions.)
1. Switch the appliance off at the power
on/off switch O / I (9). No buttons are lit.
2. Open the door (5b) to the brewing unit.
3. Slide the red lock (5d) on the brewing
unit completely to the left.
4. Press the red button (5c), grasp the
brewing unit by the recessed grips and
remove carefully.