Technical Specifications; Capacity - Heatrae Sadia ADVANCE Installer Manual

Table of Contents

Advertisement

2.3. Technical specifications

Advance/Advance Plus
Dimensions (H x W x D)
Weight
Installation
Housing
Housing and insulation
Duct connection parts /
condensate drain
Motor module
Filter caps
Mounting brackets
Filter class
Duct nozzles (4x)
Heat exchanger
Thermal efficiency
Condensate drain (2x)
Temperature sensors
*
Bypass control
Frost control
Motor (1x)
Impellers (2x)
Maximum power consumption
Power supply
Cable length
RF (built in)
Manual
*
Applies exclusively to Advance Plus

2.4. Capacity

Mode 1 minimum
Mode 1 standard
Mode 1 maximum
*
Mode 2
Mode 3 minimum
Mode 3 standard
Mode 3 maximum
Mode 3 maximum
*
Mode 2 is a calculated value, depending on the set minimum and maximum capacity.
Mode 1 and 3 can be adjusted using the potentiometers on the
motor module.
(see Adjusting the capacity on page 29).
8
760 x 597 x 290 mm
12 kg (including duct connection set)
2x 6 mm screws (not provided); on wall/ceiling/floor with min. load-bearing
2
capacity 200 kg/m
IP 30, double-insulated
EPP housing (grey), PP hollow-core panel (internal), foamed PVC faceplates
(white)
PP (black)
HIPS (black)
TPE (RAL 7040)
Galvanised steel
Standard G3 (dust filter for the first three months), then replace with G4 or F7
Ø 125 mm, top side, with leak-safe seals
Plastic counterflow exchanger (PS), not removable
Up to 91%
Ø 14 mm OD, PVC condensate hose (1 m), included
1x outside air temperature sensor; 1x exhaust air temperature sensor
Automatic control with built-in bypass valve on extraction side, 100%
Automatic frost protection (reduce fan speed at temperatures below -1°C)
DC (CE) 120 W
PA plastic (backward curved)
90 W
230 V, 50 Hz, 4-wire power cable
1.5 m (RAL 7001)
100 m in free space, 868 MHz
The user manual can also be placed in the bottom corner of the unit
3
Pressure [Pa]
Capacity [m
/h]
25
50
75
100
75
125
150
175
Power [W]
12
4
17
6
38
13
70
26.5
38
13
104
44
150
72
100
78