Convert Newer Code Types

The Symbol LS2208 supports a variety of code types that are typically not decodable by attached decoder
systems. To allow compatibility in these environments, the scanner converts these code types to more common
symbologies, as per the following chart. Symbologies not listed on this chart transmit normally.
Scan this code type:
Code 11
Chinese 2 of 5
GS1 DataBar (14, Limited, and Expanded)
Coupon Code
If you disable this parameter, when decoding these code types the scanner issues Convert Error beeps and
transmits no data.

Module Width

The standard module width is 20 µs.
For extremely slow decoder system, use this parameter to extend this module width to 50 µs.
Undecoded Scanner Emulation Interface 10 - 7
Transmitted as:
Code 39
Code 39
Code 128
Code 128
*Convert Newer Code Types
Reject Newer Code Types
*20 µs Module Width
50 µs Module Width