1. TECHNICAL DATA

Overall thermal power in kW
Useful thermal power in kW
Output power to liquid (H
Output power to room in kW
Hourly wood consumption in kg / h (wood with 20% humidity)
Yield
CO measured at 13% oxygen in %
Flue gas exhaust pipe diameter in mm
Flue diameter in mm
Water contained in the boiler in litres
Chimney pressure in (mm H
Delivery and return connector diameter (nominal bore)
External air intake section Ø in mm
Exhaust gas emission in g/s – wood
Exhaust gas temperature in ° C - wood
Optimum working temperature in ° C
Max. operating pressure in bar
Furnace opening dimensions mm (L x H)
Furnace body / furnace headpiece dimensions in mm (L x H x D)
Oven dimensions in mm (L x H x D)
Type of grill
Thermocooker height in mm
Thermocooker width in mm
Thermocooker depth (with handles) in mm
Weight in Kg
Fire prevention safety distances
The heating volume of the cookers in accordance with EN 12815, for buildings whose thermal insulation does not
correspond to the provisions regarding heat protection, is:
(30 Kcal/h x m
(40 Kcal/h x m
(50 Kcal/h x m
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater.
With temporary heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by
about 25%.
IMPORTANT: The power of the connected heating system must be proportional to the power transferred to
the water by the thermocooker; a charge which is too low does not allow regular oven
operation, while a charge which is too high prevents adequate radiator heating.
Instructions for installation, use and maintenance – EN – Rev.01
O) in kW
2
O)
2
∗ ∗ ∗ ∗ 200 mm diameter can be used with flue of no less than 6 m
3
) - favourable type of building:
3
) - less favourable type of building:
3
) - unfavourable type of building:
DSA
TERMOSUPREMA COMPACT
5m – 220x220 Ø220 ∗ ∗ ∗ ∗
VA
257 x 395 x 407
307 x 418 x 430
Movable - flat
530 m³
400 m³
320 m³
22.3
18.5
15
3.5
5.2
83
0.12
160 S/P
22
1.7 – 2
1¼"F
200
26.84
186
70-75
1,5 -
3
VEC
233 x 193
881
982
682
280