Remove the hex tool and confirm that the
4
spindle is captured into the shell by retaining
the tumbler.
The spindle is inserted properly when it can
not be removed from the housing.
5
Insert the knob. Exercise the knob and verify
that the spindle is engaged and operates
your locking mechanism as intended.
Remove the knob from the spindle with the
mechanism in the locked position.
5
1
8
If the lock shell has a non-removable finish cup or a collar/bezel that would
restrict the
MicroIQ
from being inserted flush to the cabinet, use an
appropriate lock spacer in between the
P/N: 13081-00 )
0.1" (
and 0.187" (
The spacers are available in chrome and black finish. To select your preffered
finish, add the letter "C" for chrome or "B" for black to the end of the part
number. (e.g.: 13081-00-C )
Select appropriate mounting screw. If a lock spacer is required, a mounting
screw must be used.
Mount as shown on page 8.
Remove the backing from the foam tape (underneath the lock body) and insert
the
MicroIQ
in the desired orientation until it is flush with the face of your panel.
Allow tape to cure for 72 hours.
7
9
OPTIONAL:
If your locking mechanism does not have a
rotational stop, insert one of the provided
cam stops to match the desired rotation.
11
Insert the knob at LOCKED position and
rotatate to verify that the cam stop was
positioned correctly.
Confirm that your mechanism is locked
when the knob points to the lock icon
9
MicroIQ
and the cabinet. Spacers of
P/N: 13081-10 )
are available from TriTeq.
6
Remove the knob and insert the provided
spindle spacer. Align the spline of the
spindle spacer with one valley from your
lock shell.
7
The
MicroIQ
can be mounted to the cabinet with
the enclosed screw or double stick tape or both.
The installation template at the end of this
manual can be used to drill the mounting hole
for the
MicroIQ
. A wood screw and a
self-tapping metal screw are provided.
12
If your locking mechanism requires the knob to rotate CCW from "locked"
to "unlocked", rotate your knob only 45° and using the hex tool, fasten the
knob to the spindle from the indicated location.
If your locking mechanism requires the knob to
13
rotate CW from "locked" to "unlocked", rotate your
knob only 45°. Using the hex tool, fasten the knob to
the spindle from the indicated location.
1/8" diameter hole
for metal
3/32" diameter
3/32" diameter
hole for wood
hole for wood
6
Bezel
Spindle
Spacer
Lock
Spacer
8
10