Page 1
Series 2200 Operating Instructions Installation Instructions Visit the link below or scan the QR code to watch a detailed installation video: http://triteqlock.com/2200...
Page 2
After the lock, temperature probe, power supply, battery, and wiring are connected per the installation instructions, the system should be tested as follows to confirm full functionality. SPECIFICATIONS: Primary Power: 120 AC -12V DC 500mA UL Certified wall converter Back Up Power: 9V NiCad rechargeable battery Test Button: For Health Department to confirm proper locking function Cooler Protection Temperature: 41F or greater for 30 minutes Freezer Protection Temperature: 0F or greater for 30 minutes...
Page 3
With the doors closed, insert a pencil or a thin non-metallic tool into the test button hole. Press and hold the test button in for 60 seconds. The doors should be locked and the RED LED should be triple flashing. Point the P1 key fob at the lock LED and press the fob button.
Page 4
Fresh IQ 22xx Troubleshooting Guide Lock Cooler/Freezer LED State Problem Possible Cause Action Condition Condition Locked Solid GREEN Warm Faulty component Probe or lock failure Replace probe or lock Check alignment of lock or Locked Solid GREEN Cold Unit should be unlocked Lock misaligned or failed replace lock Locked...
Page 5
Triteq’s sole obligation under this warranty, and the original purchaser’s sole remedy under this warranty is limited to either one of the following, as Triteq shall elect in its discretion: (a) repair or replace the defective Product, or (b) refund the purchase price paid for the defective Product.
Need help?
Do you have a question about the FreshIQ 2200 Series and is the answer not in the manual?
Questions and answers