Installation; Installation Requirements; Unpacking; Location - Blue Seal GP513 Installation And Operation Manual

Evolution series
Hide thumbs Also See for GP513:
Table of Contents

Advertisement

Installation

Installation Requirements

NOTE:
 It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local gas, health and safety requirements.
 This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, appliance is
installed in.
Blue Seal Gas Griddles are designed to provide years of satisfactory service and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia:
New Zealand:
United Kingdom:
Ireland:
Installations must be carried out by qualified persons only. Failure to install equipment to the
relevant codes and manufacturer's specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.

Unpacking

 Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
 Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
 Ensure 2 front adjustable feet and rear rollers are securely fitted.
 Report any deficiencies to distributor who supplied appliance.
 Check available gas supply is correct to as shown on rating plate located behind front control panel
and on inner face of right hand panel.

Location

1.
Installation must allow for a sufficient flow of fresh air for combustion air supply.
Natural Gas
LPG / Butane
Town Gas
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. Minimum installation clearances shown overleaf are to be adhered to.
4.
Position appliance in its approximate working position.
5.
All air for burner combustion is supplied from beneath unit. Legs must always be fitted and no
obstructions placed beneath or around base of unit, as obstructions will cause incorrect operation
and / or failure of appliance.
6.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by the installation person.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to
appliance flue outlet.
- AS5601
- NZS5261
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- BS5440
- IS 820
Combustion Air Requirements:
GP513
GP514
3
3
10.5m
/hr
14m
/hr
3
3
11m
/hr
15m
/hr
3
3
10.5m
/hr
14m
/hr
- Gas Installations.
- Gas Installation.
- Installation of Catering Appliances.
- 1 & 2 Installation Flueing & Ventilation.
- Non - Domestic Gas Installations.
GP516
GP518
3
3
21m
/hr
28m
3
3
22m
/hr
29m
3
3
21m
/hr
28m
10
/hr
/hr
/hr

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp514Gp516Gp518

Table of Contents