Re-Setting Overtemp Device (All UK and Optional Non-UK Models).

This griddle is fitted
with an overtemp device which isolates gas supply to burners should gas control
system or thermostat malfunction, thus preventing griddle overheating. If pilot fails to ignite after several
attempts, ensure that overtemp is checked to ensure that it has not tripped.
1.
To reset overtemp, remove gas control
knobs from front of griddle.
2.
Slacken 2 screws securing front control
panel and carefully remove control
panel, ensuring that leads to piezo
igniter are disconnected from rear of
piezo buttons.
3.
Using a small screwdriver, depress
centre of overtemp reset button.
4.
Re-connect piezo igniter leads to rear
of piezo igniter buttons.
5.
Refit front control panel and secure in
position with 2 securing screws.
6.
Refit gas control knobs to gas spindles.
7.
Attempt to re-light pilot burners as shown above. Should pilot burners still not ignite, call a qualified
service person to investigate problem.
Should any abnormal operation like;
- ignition problems,
- abnormal burner flame,
- burner control problems,
- partial or full loss of burner flame in normal operation, be noticed, appliance requires
IMMEDIATE service by a qualified service person and should not be used until such service is
carried out.
For Refrigeration Cabinet Operation refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
O v e r t e m p
reset button
IMPORTANT:
15
Operation
Overtemp fitted to
Gas Control Valve.