SITE PREPARATION

Electrical

Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit,
servicing only this appliance is required.
The electrical outlet must be placed so
IMPORTANT NOTE:
the grounding prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
Model UC-24RO is designed and safe for use in outdoor
applications. When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock. A GFCI is not recommended for use with
other undercounter models and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
LEFT SIDE
OF OPENING
1
2"
15
/
"
2
(51)
(394)
3"
(76)
FLOOR
Electrical supply location.
115 VAC, 60 Hz
15 amp
3-prong grounding-type

Plumbing

Installation must comply with all applicable plumbing codes.
For model UC-24CI, the water supply should be located
within the shaded area shown in the illustration below.
The water supply line should be connected to the house
supply with an easily accessible shut-off valve. Do not use
self-piercing valves.
A reverse osmosis system can be used provided there is
constant water pressure of 20–100 psi
to the unit at all times. A copper line is not recommended
for this application.
PLUMBING REQUIREMENTS
Water Supply
Pressure
Excess Line for Connection
LEFT SIDE
OF OPENING
1
2"
15
/
"
2
(51)
(394)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
Water supply location.
supplied
(1.4–6.9 bar)
1
/
" OD copper, braided
4
stainless steel or PEX tubing
20–100 psi
(1.4–6.9 bar)
36"
(914)
|
subzero.com