Section 4 − Installation; Installing Welding Generator; Installing Exhaust Pipe - Miller Electric 500DX R Owner's Manual

Engine driven welding generator
Table of Contents

Advertisement

4-1. Installing Welding Generator

Movement
Y
Do Not Lift Unit From End
OR
Grounding
2

4-2. Installing Exhaust Pipe

Tools Needed:
1/2 in
OM-129 647 Page 14
SECTION 4 − INSTALLATION
Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
1
OR
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
Top View
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
3
4
GND/PE
2
install1 3/96 − Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
exh_pipe2 4/96 − ST-154 089-A / ST-154 611 / ST-180 933-B
Location
OR
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y
If unit does not have GFCI
receptacles,
use
GFCI-
protected extension cord.
Y
Stop engine and let cool.
Y
Do not blow exhaust toward
air cleaner or air intake.