Section 2 − Definitions; Symbols And Definitions; Section 3 − Specifications; Specifications - Miller Electric 500DX R Owner's Manual

Engine driven welding generator
Table of Contents

Advertisement

2-1. Symbols And Definitions

Stop Engine
Do Not Switch
While Welding
Check Injectors/
Pump
Positive
A
Amperes
On
Stick (SMAW)
Welding
Time
3
Three Phase
3-1. Weld, Power, And Engine Specifications
Weld
Welding
Output
Mode
Range
CC/DC
45 − 600 A
CV/DC
14 − 38 V
(Optional)
SECTION 2 − DEFINITIONS
Start Engine
Battery (Engine)
Check Valve
Clearance
Negative
V
Volts
Temperature
Constant Current
(CC)
h
Hours
Read Operator's
Manual
SECTION 3 − SPECIFICATIONS
Maximum
Rated Welding
Open-
Output
Circuit
Voltage
95 (88 in CC
500 A, 40 Volts DC,
mode on
60% Duty Cycle
units with CV)
400 A, 36 Volts DC,
48
100% Duty Cycle
Ether Starting Aid
Circuit Breaker
Fuel
Certified/Trained
Mechanic
Panel/Local
Output
MIG (GMAW)
Welding
s
Seconds
Auxiliary Power
Engine
Rating
Deutz F3L-912
Single-Phase,
Air-Cooled,
3 kVA/kW, 25 A,
3 kVA/kW, 25 A,
Three Cylinder,
Three-Cylinder,
120 V AC, 60 Hz
41.5 HP Diesel
Engine
Engine
Engine Oil
Protective Earth
(Ground)
Welding Arc
14
Remote
Alternating
Current
Constant Voltage
(CV)
1
Single Phase
Fuel Capacity
23 gal (87 L)
23 gal (87 L)
OM-129 647 Page 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Om-129Big blue 500dx

Table of Contents