Electrode Lead; Spark Generator; Resistor - Baxi Bermuda SP3 Installation And Servicing Manual

Hide thumbs Also See for Bermuda SP3:
Table of Contents

Advertisement

1
2
Supplied By www.heating spares.co Tel. 0161 620 6677

Electrode Lead

Remove the insulating sleeve from the body of the
electrode. Disconnect the electrode lead from the
electrode.
Disconnect the electrode lead from the spark
generator.
Undo the screw holding the orange panel to the
chassis. Lift the panel upwards and withdraw the
sleeve and lead.
Thread the new electrode lead through the
insulating sleeves. Fit the new electrode
lead to the spark generator and
electrode.
Re-assemble the components in
the reverse order to dismantling.

Spark Generator

Remove the front screw holding the
spark generator in place, and release
the rear screw, enabling the
generator to be removed.
Disconnect the electrical
connections and electrode lead.
Fit the new spark generator and re-
assemble all components in the
reverse order to dismantling.

Resistor

Remove the two screws securing the light shield
bracket. Unclip the resistor from the side frame.
Disconnect the two resistor wires from the terminal
strip. Replace resistor and refit in reverse order.