10 Maintenance
Fig.74
Electrode distance
8.0
±
1
4.5
BO-7696477-2
68
Combi 2
±
0.5
10.3.9

Electrode distances

Verify the distances between the electrode and the burner and between
10.3.10

Water unit

Caution
Do not use tools to remove components from inside the water unit
(e.g. filter).
For certain user areas, where domestic water hardness values exceed
20 °F (200 mg of calcium carbonate per litre of water) it is recommended
to install a polyphosphate batcher or equivalent system complying with
the prevailing standards.
CLEANING THE DOMESTIC WATER FILTER
The domestic water filter is housed inside a suitable removable cartridge
positioned on the cold water inlet (B). Proceed as follows to clean:
1. Disconnect the power supply to the boiler;
2. Close the domestic water inlet cock;
3. Empty the water from the domestic water circuit by opening a user
cock;
4. Remove the clip (1-B) as shown in the figure and remove the
cartridge (2-B) containing the filter, taking care not to apply excessive
force;
5. Remove any impurities and deposits from the filter;
6. Fit the filter back inside the cartridge and reinsert it into its seat,
securing it with its clip;
Notice
If the O-rings in the water unit need to be replaced and/or cleaned,
do not use oil or grease as a lubricant, but only Molykote 111.