Baxi Solo HE A Range User's Operating Instructions & Important Warranty Information

Baxi Solo HE A Range User's Operating Instructions & Important Warranty Information

Wall mounted powered flue condensing boilers gas fired central heating units
Hide thumbs Also See for Solo HE A Range:

Advertisement

User's Operating Instructions &
Important Warranty Information
Solo HE
Range
A
Wall Mounted Powered Flue Condensing
Boilers Gas Fired Central Heating Units
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
© Baxi Heating UK Ltd 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solo HE A Range and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Baxi Solo HE A Range

  • Page 1 Solo HE Range Wall Mounted Powered Flue Condensing Boilers Gas Fired Central Heating Units Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2012...
  • Page 2: Table Of Contents

    Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk © Baxi Heating UK Ltd 2012 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any...
  • Page 3: Quick Reference Guide

    ) is ON or FLASHING, press the Reset button until the High red light goes OFF. If this occurs frequently a Reset fault is indicated and you should contact your installer. LED Light Lockout (Red) © Baxi Heating UK Ltd 2012...
  • Page 4: Troubleshooting

    ? SERVICE ENGINEER. High Reset Lockout (Red) Press the Reset Button until the red light goes off. High If the light Reset Reset Button does not go out or keeps coming on. © Baxi Heating UK Ltd 2012...
  • Page 5 If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible © Baxi Heating UK Ltd 2012...
  • Page 6: Clearances

    11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this For Servicing Purposes would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 298mm In Operation Fig. 2 © Baxi Heating UK Ltd 2012...
  • Page 7: Care Of The Boiler

    1. The boiler does not have integral frost protection. It is recommended that the installer fits a suitable protection device to the system controls if required. For frost protection the boiler must not be switched off at the isolation switch on the wall. © Baxi Heating UK Ltd 2012...
  • Page 8: Legislation

    The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The Benchmark Checklist may be required in the event of any warranty work. © Baxi Heating UK Ltd 2012...
  • Page 9: Notes

    6.0 Notes © Baxi Heating UK Ltd 2012...
  • Page 10: Notes

    6.0 Notes © Baxi Heating UK Ltd 2012...
  • Page 11: Emergency

    Telephone the National Gas Emergency Service on:- 0800 111 999 Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. © Baxi Heating UK Ltd 2012...
  • Page 12: Warranty & Service

    Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 013 7989.