Section 3 − Installation; Specifications; Duty Cycle And Overheating - Miller Electric Invision 456MP Owner's Manual

230/460 and 575 volt models
Table of Contents

Advertisement

3-1. Specifications

Input
Rated Welding
Power
Power
Output
Output
450 A @ 38 Volts DC,
Three
100% Duty Cycle;
Phase
565 A @ 43 Volts DC,
60% Duty Cycle
*While idling

3-2. Duty Cycle and Overheating

100% Duty Cycle At 450 Amperes
Continuous Welding
Overheating
SECTION 3 − INSTALLATION
Maximum
Amperes Input At Rated
Open-
Load Output 60 Hz,
Voltage
Circuit
Three-Phase
Range
Range
Voltage
Voltage
230 V
DC
50.8
10 − 38
95
(0.14*)
0
Minutes
KVA
460 V
575 V
230/460
27.8
24.4
21.2
(0.09*)
(0.12*)
(0.06*)
60% Duty Cycle At 565 Amperes
6 Minutes Welding
15
OR
Reduce Duty Cycle
KW
575
230/460
575
24.3
19.2
19.0
(0.12*)
(0.04*)
(0.07*)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
4 Minutes Resting
A/V
duty1 4/95 − SA-181 560
OM-193 267 Page 11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents