5-1. Overview of Programs

Program #
Wire Type
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Silicon Bronze
16
Metal Core
17
Metal Core
18
Metal Core
SECTION 5 − PROGRAMS
Wire Size
Steel
.035 in
Steel
.045 in
Steel
.052 in
Steel
.062 in
Stainless
.035 in
Stainless
.045 in
4043AL
.035 in
4043AL
.047 in
4043AL
.062 in
5356AL
.035 in
5356AL
.047 in
5356AL
.062 in
Nickel
.035 in
Nickel
.045 in
.035 in
.045 in
.052 in
.062 in
Shielding Gas
IPM: Min
Ar/CO
2
Ar/CO
2
Ar/CO
2
Ar/CO
2
98Ar/2CO
2
98Ar/2CO
2
Argon
Argon
Argon
Argon
Argon
Argon
75Ar/25He
75Ar/25He
Argon
Ar/CO
2
Ar/CO
2
Ar/CO
2
IPM: Max
80
750
80
750
70
750
60
400
100
750
90
750
240
840
150
750
120
520
350
850
200
750
180
580
120
670
100
600
120
750
100
750
50
750
50
500