Miller Electric Invision 456MP Owner's Manual page 35

230/460 and 575 volt models
Table of Contents

Advertisement

IPM
Trim
120
0
160
10
200
20
240
30
280
40
320
50
360
60
400
70
440
80
480
90
520
100
IPM
Trim
350
0
400
10
450
20
500
30
550
40
600
50
650
60
700
70
750
80
800
90
850
100
IPM
Trim
200
0
255
10
310
20
365
30
420
40
475
50
530
60
585
70
640
80
695
90
750
100
Program 9 −− 1/16 .062 Aluminum 4043 −− Argon
Peak Amp
Background Amp
258
56
270
89
298
115
336
134
367
148
400
157
421
169
440
181
461
192
480
204
498
216
Program 10 −− .035 Aluminum 5356 −− Argon
Peak Amp
Background Amp
200
65
216
72
230
80
242
87
251
94
261
101
272
108
284
117
296
127
301
131
303
134
Program 11 −− .047 Aluminum 5356 −− Argon
Peak Amp
Background Amp
240
47
270
58
301
65
320
72
341
80
350
91
388
101
411
110
421
120
440
131
461
141
Freq.
Pulse Width
40
2.15
60
2.40
80
2.60
106
2.89
122
3.15
134
3.35
144
3.55
154
3.70
164
3.90
174
4.05
180
4.18
Freq.
Pulse Width
54
1.90
66
1.95
78
2.00
88
2.05
96
2.10
104
2.17
112
2.24
121
2.32
130
2.40
137
2.45
140
2.48
Freq.
Pulse Width
55
2.10
80
2.20
98
2.30
110
2.40
120
2.50
130
2.60
140
2.70
153
2.80
163
2.90
168
2.95
170
3.00
Starting Amps
550
649
649
702
720
737
748
758
772
787
801
Starting Amps
451
451
451
501
501
501
501
501
550
550
550
Starting Amps
501
600
600
652
652
652
652
702
702
702
702
OM-193 267 Page 31