Glass Specifications; Non-Combustible Materials; Combustible Materials; Electrical Codes - Heatilator C40 Installation Manual

Epa certified woodburning fireplace
Hide thumbs Also See for C40:
Table of Contents

Advertisement

B. Glass Specifications
This fireplace is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
NOTICE: This installation must conform with local codes. In the
absence of local codes you must comply with the UL127, (UM)
84-HUD and NFPA211 in the U.S.A. and the ULC 610-M87
and CAN/CSA-B365 Installation Codes in Canada.
WARNING! Risk of Fire! Hearth & Home Technologies
disclaims any responsibility for, and the warranty and agen-
cy listing will be voided by the following actions.
DO NOT:
• install or operate damaged fireplace
• modify fireplace
• install other than as instructed by Hearth & Home
Technologies
• operate the fireplace without fully assembling all
components
• overfire
• install any gas log set
• install any component not approved by Hearth & Home
Technologies
• install parts or components not Listed or approved
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualified
installer, service agency or your dealer.
C. Non-Combustible Materials
Materials which will not ignite and burn, composed of
any combination of the following:
-
Steel
-
Brick
-
Concrete
-
Glass
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace at 750° C
WARNING! Risk of Fire!
Hearth & Home Technologies is not responsible for
discoloration, cracking or other material failures of
finishing materials due to heat exposure or smoke.
• Choose finishing materials carefully.
Heatilator • C40 Constitution • 480-2340 Installation Manual • Rev K • 8/24/15
- Iron
- Tile
- Slate
- Plasters
D. Combustible Materials
Materials made of or surfaced with any of the following
materials:
-
Wood
-
Plant fibers
-
Plywood/OSB
Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
E. Electrical Codes
NOTICE: This fireplace must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code ANSI/
NFPA 70-latest edition or the Canadian Electric Code
CSA C22.1.
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in damp locations.
WARNING! Improper installation, adjustment, alteration,
service or maintenance can cause injury or property dam-
age.
- Compressed paper
- Plastic
- Sheet rock (drywall)
5