Product Specific & Important Safety Information
Product Specific & Important Safety Information
A. Appliance Certification
This fireplace system has been tested and listed in ac-
cordance with UL127 and ULC-S610-M87 and (UM)84-
HUD standards for installation and operation in the United
States and Canada as described in this manual.
Check with your local building code agency before you
begin your installation to ensure compliance with local
codes, including the need for permits and follow-up in-
spections. Be sure local building codes do not supersede
UL specifications and always obtain a building permit so
that insurance protection benefits cannot be unexpectedly
cancelled.
Heat & Glo is a registered trademark of Hearth & Home
Technologies.
Model:
Constitution
Laboratory:
OMNI Test Laboratories, Inc.
Report No:
061-S-50-2
Type:
Wood Fireplace
Standard:
UL127 and ULC-S610-M87 and
(UM) 84-HUD, Manufactured
Home Approved.
The Heatilator Constitution meets the U.S. Environmental
Protection Agency's crib wood emission limits for wood
heaters sold after May 15, 2015.
4
Heatilator • C40 Constitution • 480-2340 Installation Manual • Rev K • 8/24/15
BTU & Efficiency Specifications
EPA Certification #: 569
EPA Certified Emissions: 3.3 grams per hour
*LHV Tested Efficiency: 77.2 %
**HHV Tested Efficiency: 71.5%
***EPA BTU Output: 11,300 to 51,200 / hr.
****Peak BTU/Hour Output: 74,900
Vent Size: 6 inches
Firebox Size: 2.7 cubic feet
Recommended Log Length: 22 inches
* * Weighted average LHV (Low Heating Value) efficiency using
Douglas Fir dimensional lumber and data collected during EPA
emission test. LHV assumes the moisture is already in a vapor
state so there is no loss in energy to vaporize.
****Weighted average HHV (High Heating Value) efficiency using
Douglas Fir dimensional lumber and data collected during EPA
emission test. HHV includes the energy required to vaporize the
water in the fuel.
***A range of BTU outputs based on EPA Default Efficiency and
the burn rates from the low and high EPA tests, using Douglas
Fir dimensional lumber.
****A peak BTU out of the appliance calculated using the maxi-
mum first hour burn rate from the High EPA Test and the BTU
content of cordwood (8600) times the efficiency.
Fuel Seasoned Cord Wood