OPERATION

Before taking any measurements, read the Safety Information Section.
Always examine the instrument for damage, contamination (excessive dirt,
grease, etc.) and defects. Examine the test leads for cracked or frayed
insulation. If any abnormal conditions exist do not attempt to make any
measurements.
H
Button
In voltage, current, frequency and doide functions, Press "
H
" button to toggle
in and out of the Auto Hold mode, the "
H
" annunicator is displayed. In Auto
hold mode, the meter will capture and hold the first stable non-zero(>100
digits) reading after a zero reading(<100 digits). Several consecutive mea-
surements can be held and displayed without pressing the (A-H) buttion.
Simply by shorting the test leads together between measurements. In resis-
tance, continuity and temperature functions, press "
H
" button to toggle in and
out of the Data Hold mode, the "
H
" annunicator is displayed.
PEAK HOLD Button: (only AC functions 40-60Hz)
Press "PEAK" button to toggle in and out of PEAK Hold mode. In the PEAK
Hold mode, the "MAX
P
" annunciator is displayed. [Accuracy: ±(10% rdg +
10dgts), effect reading: 800~4300]