Troubleshooting - Martin MAC Quantum Profile Safety And Installation Manual

475 w long-life led engine
Hide thumbs Also See for MAC Quantum Profile:
Table of Contents

Advertisement

Troubleshooting

Problem
One or more of the fixtures is
completely dead.
Fixtures reset correctly but
respond erratically or not at all
to the controller.
Timeout error after fixture reset.
Mechanical effect loses
position.
Light output cuts out
intermittently.
22
Probable cause(s)
No power to fixture.
Fuse blown or internal fault.
Bad data link.
Data link not terminated.
Incorrect addressing of fixtures.
One of the fixtures is defective and is
disturbing data transmission on the link.
Effect requires mechanical adjustment.
Mechanical train requires cleaning,
adjustment, or lubrication.
Fixture is too hot.
Table 2: Troubleshooting
MAC Quantum Profile Safety and Installation Manual
Remedy
Check that power is switched on and cables are
plugged in.
Contact Martin™ Service or authorized service
partner. Do not remove base or yoke covers,
attempt to replace a fuse or carry out any repairs or
service that are not described in this Safety and
Installation Manual unless you have both
authorization from Martin™ and official Martin™
service documentation.
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables.
Insert DMX termination plug in data output socket
of the last MAC Quantum Profile on the data link.
Check fixture address and protocol settings.
Unplug the XLR in and out connectors and connect
them directly together to bypass one fixture at a
time until normal operation is regained. Have the
fixture serviced by a qualified technician.
Contact Martin™ Service or authorized Martin™
service partner.
Contact Martin™ Service or authorized Martin™
service partner.
Allow fixture to cool.
Clean fixture.
Reduce ambient temperature.

Hide quick links: